About Placement

This unit performs forced cooling by means of a cooling fan. Give attention to the
following points.

•

Never block the cooling-fan intake port or ventilation port in the rear panel. Doing so
may cause the temperature of the unit’s interior to rise, resulting in malfunction caused
by heat.

•

Clean away any buildup of dust in the intake port or ventilation port using a vacuum
cleaner or the like.

●

This unit can be installed in a rack. When installing the unit in a rack, to ensure efficient
cooling, give attention to the following points.

•

Ensure that the location provides good air flow and ventilation.

•

Never block the cooling-fan intake port or ventilation port in the rear panel.

•

Avoid using the S-4000D in sealed-type rack mounts. As this type of rack does not
permit heated air within the rack to be expelled, the heated air is drawn into the
S-4000D as a result, thus preventing adequately efficient cooling.

•

If the rack’s rear panel is not removable, ensure that a ventilation port or exhaust fan is
provided at the top of the rack’s rear panel to expel any accumulated heat.

•

If the S-4000D is mounted in a portable rack, remove both the front and rear rack covers
before use to ensure that the S-4000D’s front and rear panels remain unobstructed.

•

When installing the unit on a rack, detach the rubber feet from the bottom of the unit.

●

Use due caution when mounting the S-4000D in a rack or other enclosure so you don’t
get your fingers wedged or pinched.

Important Notes When Installing

Cooling-fan Intake Port and Ventilation Port

When Installing in a Rack