Storage, Maintenance – RedMax BRUSHCUTTERS BCZ2400S User Manual

Page 22

Advertising
background image

22

10. Storage

• Aged fuel is one of major causes of engine

starting failure. Before storing the unit, empty the
fuel tank and run the engine until it uses all the
fuel left in the fuel line and the carburetor. Store
the unit indoor taking necessary measures for
rust prevention.

9. Maintenance

sure that the muffler is clean and free of
wood chips, leaves, and other waste before
use.

• Check the intake air cooling vent and the area

around the cylinder cooling fins after every 25
hours of use for blockage, and remove any
waste which has attached itself to the
brushcutter. Note that it is necessary to remove
the engine cover shown in (MA7) in order to be
able to view the upper part of the cylinder.

• If waste gets stuck and causes blockage around

the intake air cooling vent or between the
cylinder fins, it may cause the engine to
overheat, and that in turn may cause mechanical
failure on the part of the brushcutter. (MA7)

(1) cylinder
(2) intake air cooling vent (back)

PROCEDURES TO BE PERFORMED AFTER
EVERY 100 HOURS OF USE

1. Remove the muffler, insert a screwdriver into the

vent, and wipe away any carbon buildup. Wipe
away any carbon buildup on the muffler exhaust
vent and cylinder exhaust port at the same time.

2. Tighten all screws, bolts, and fittings.
3. Check to see if any oil or grease has worked its

way in between the clutch lining and drum, and if
it has wipe it away using oil-free, lead-free
gasoline.

IMPORTANT

MA8

(1)

(2)

MA7

Advertising