Controller Specifications & Dimensions
Aspect Ratios:
Anamorphic, Letterbox, 4:3
(on either 16:9 or 4:3 screens)
Input Standards:
NTSC, PAL
Outputs:
Native Resolution: 768p;
HD Pass-Through: Up to 1080P
Inputs:
(1) Composite, (1) S-Video,
(1) Component, (1) Pass-through
Control Options:
Infrared (with discrete on/off, aspect
ratio and source selection), RS-232
and Front Panel
Screen Trigger/
Masking Outputs:
(2) 12V DC, 1/8A
Bandwidth:
Video Inputs: 5.5 Mhz,
Pass-Through: 100 Mhz
Power Requirements:
100 - 240V AC (auto sensing),
50/60 Hz, 15W
Operating Environment: 41° - 95° F (5° - 35° C),
0 - 90% Humidity (non-condensing)
Dimensions:
Width: 17 1/2 in. (444.50 mm)
(w/out feet)
Depth: 16 in. (406.40 mm)
Height: 3 1/2 in. (88.90 mm)
Weight: 16 lbs. (7.3 kg)
Included Accessories:
Rack mounting brackets
Regulatory Approvals:
Complies with FCC Class 'B', CE,
C-tick
Limited Warranty:
(2) Two years parts and labor from
the date of delivery to the end user.
Front Panel
Rear Panel
Top Panel