Raypak MVB TYPE B 504-2004 User Manual

Type p

Advertising
background image

Catalog No.: 6000.29B

Effective: 7-15-08

Replaces: 1-1-08

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

85% Thermal Efficiency

100% Factory Fire Tested

Minimum Acceptable Inlet Water Temperature: 105°F

Full Safety Diagnostics with History

Footprint: Less Than 5-1/2 ft

2

Limited Twenty-Year Thermal Shock Warranty

Limited Five-Year Heat Exchanger Warranty

On/Off Firing

Soft-Start Modulating Controller with LCD Display

Status Display Lights

Heat Exchanger

Bronze Headers
ASME HLW Stamped

160 PSIG Working Pressure

National Board Approved
Cupro Nickel Fin Tubing
ASME Powder-Coated Tube Sheet
Silicone High Temp O-Rings
ASME Pressure Relief Valve,

125 PSIG

Temperature and Pressure Gauge,

Shipped Loose

Stainless Steel Evaporator Plate
Bronze Pump (See table on pg. 2)
Drain Valves (2)
Air Vent

Control

120V, 60Hz, 1Ø, Power Supply
120/24V 60Hz Transformer
Ignition Module

3-Try – Standard
Single-Try – Option C-6

Hot Surface Ignition (HSI)
Remote Flame Sensor
High Limit, Auto Reset, Adj., 140°F
High Limit, Manual Reset, Fixed

Models 504-1504: 175°F
Models 2004: 200ºF

On/Off Power Switch
Flow Switch, Mtd
Blocked Vent Pressure Switch
Combustion Air Proving Switch
Pump Switch
Pump Time Delay
Diagnostics Panel

Control (cont.)

On/Off Digital Poolstat, 106°F Max
Water Temperature Sensors (3) with

Immersion Well

Burner

Ultra-Low NOx: Less than 20 PPM

Gas Train

Fuel

Natural Gas
Propane

Zero Governor Regulator
Dual-Seat Combination Valve
On/Off Firing with Soft-Start

Construction

Indoor/Outdoor Construction
Enclosed Front Controls
PolyTuf Powder Coat Finish
Rear Connections (Water, Electrical,

Gas, Vent, Combustion Air)

Design Certification

Models 504-1504: ANSI Z21.56/
CSA 4.7
Model 2004: ANSI Z21.10.3/CSA 4.3

Venting

Vent Termination Cap

Outdoor – Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)

Combustion Air

In-Line Filter Kit – Option D-17
Air Intake Elbow – Option D-16

Extractor – Optional

By others
Not required

Temperature Controllers

B-26 TempTracker Digital Controller,

Up to 2 Heaters

B-21 TempTracker Digital Controller,

Up to 4 Heaters

Y-241 Electronic Sequencer,

Up to 4 Heaters

Y-281 Electronic Sequencer,

Up to 8 Heaters

Options

F-10 Low Water Cut-Off, Remote

Probe

P- Cold Water Run
P- H-style Bypass, Non-Ferrous
S-1

Low Gas Pressure Switch,
Manual Reset

S-2

High Gas Pressure Switch,
Manual Reset

Regulatory Agency Requirements

MVB

®

- Type P

Pool Heaters

Models 504-2004

Pump included
standard

L

W