background image

RIC-E1 Installation and Operation Manual

Appendix D IR-IP Interface Module

Device Control

D-25

Erasing Configuration

Selecting this item allows you to reset all the configuration parameters to their
default values.

• Do this only if you need to reconfigure the module anew (all the parameters).
• After erase confirmation all connections with the IR-IP module will be lost. For

instructions on further configuration, refer to

Performing Preliminary

Configuration

on page D-8.

Resets Menu

The Resets menu allows you to perform reset of IR-IP, or its interfaces.
This operation can be used to restore normal operation after service is disrupted
by an abnormal condition. Any data stored in the IR-IP buffers is discarded, and
the flow of traffic is temporarily interrupted.

To access the Resets menu:
• From the Device Control menu, type 3.

The following screen appears:

IR_IP

<IR-IP>

S/W Ver. 1.21 31/IR (date)


Quick Setup
Management Access
Advanced Setup
Device Control
.....................................................................

New Software Download

View error LOG

Erase

Configuration

Resets
=====================================================================

1. Reset Device

2. Reset LAN

3. Reset WAN

Press one of the numbers to select or ESC:

Figure D-21. Resets Menu

Resetting the Device

To restart IR-IP:
• From the Resets menu, type 1.

You will be prompted to confirm the reset operation.

Resetting the device will restart the IR-IP interface module, and therefore traffic flow

is temporarily interrupted, and the Telnet connection is lost.

Resetting the LAN Interface

To reset the LAN interface:
• From the Resets menu, type 2.

You will be prompted to confirm the reset operation.

Note