INSTALLER settings (continued)

ENERGY EFFICIENT RECOVERY

When turned on, the thermostat will look up to two hours before the next event and anticipate when

to turn on to reach the desired temperature.

DEADBAND SETPOINT

Deadband is used with the AUTO CHANGEOVER feature. The deadband is the temperature

difference from the setpoint temperature during which the heating or cooling will not be turned on.

This is adjustable from 2-8°F (1.0-4°C).

SECURITY CODE

Enter a code to prevent changes to the INSTALLER settings.

23

INSTALL MENU

SELECT

ENTER SECURITY CODE

FOR INSTALLER

SETTINGS

0

0 0 0

INSTALL MENU

SELECT

ENERGY EFFICIENT

RECOVERY

DISABLE

ENABLE

INSTALL MENU

SELECT

AUTOCHANGE DEADBAND

3

˚F