2.1.2
Vertical Timing
2.1.2.1
Normal Full Scanning
(Setting 10H: 1XX00XXX, 11H: XXX0X000)
1 H = 30.063 μs, 16.000 Hz
2.1.2.2
Partial Full Scanning
(Setting 10H: 1XX01XXX, 11H: XXX0X000)
1 H = 30.063 μs, 16.100 Hz
※ By transferring the blanking period pixels at a high rate, the frame rate of the partial full scanning can
be increased compared to that of the normal full scanning.
Video out
FVAL
2079H
One vertical (1V)
2058H
21H
2058H
21H
Video output active term
1
2
2
0
5
7
2
0
5
8
21H
Vertical
blanking
Vertical
blanking
21H
LVAL
DVAL
Video out
FVAL
2066H
One vertical (1V)
2058H
8H
2058H
8H
Video output active term
1
2
2
0
5
7
2
0
5
8
8H
Vertical
blanking
Vertical
blanking
8H
LVAL
DVAL