Installing the water heater.

18

A Water Heater Location

❑

Installed OUTDOORS.

❑

Close to area of mostly used outlet.

❑

Protected from freezing temperatures.

❑

Proper clearance from combustible surfaces

observed.

❑

Sufficient fresh air supply for proper operation of

water heater.

❑

Air supply free of corrosive elements and

flammable vapors.

❑

Provisions made to protect area from water

damage.

❑

Sufficient room to service heater.

❑

Combustible materials, such as clothing, cleaning

materials, rags, etc. clear of the heater and vent

piping.

❑

Water heater is properly attached to the wall.

B. Water Supply

❑

Water supply has sufficient pressure.

❑

Air purged from water heater and piping.

❑

Water connections tight and free of leaks

❑

Water filter is clean and in place.

❑

Materials used are as instructed in this manual.

❑

Water pipes are insulated.

C. Gas Supply

❑

Gas type matches rating plate.

❑

Gas supply pressure is sufficient for the water

heater.

❑

Gas line equipped with shut-off valve, union and

sediment trap.

❑

Approved pipe joint compound used.

❑

Soap and water solution used to check all

connections and fittings for possible gas leak.

❑

Gas Company inspected installation (if required).

D. Relief Valve

❑

Pressure Relief Valve properly installed and

discharge line run to open drain

❑

Discharge line protected from freezing.

E. Electrical Wiring

❑

Voltage matches rating plate.

❑

Water heater is properly grounded.

❑

Wiring meets all local codes.

❑

Water heater is hardwired.

Installation Check List