Features, Appliance specifications, Flue manifolds – Rinnai ENERGYSAVER ES38 User Manual

Page 5

Advertising
background image



Rinnai Corporation ES38 Manual

Features

Restarts automatically when ignition or combustion

fails.

Clean Heating Forced Flue Type

Easy Operation One-Touch Ignition

Sensible Temperature Control Feature

Comfortable Room Temperature Control and

Display

Warm Air Outlet at Floor Level (keeps your feet

warm)

Function Lock

Room Temperature Setting Memory

Clean the Air Filter - Indicator Lamp

Energy Saving Economy Setting

Humidifier Tray

Air Flow Directional Louvers

Direct Vent Easily Installed

Proportional Heating Variable Capacity

Hush! Quiet Operation

Modern Design Minimizes Floor Space

Requirements

Fault Code Message Display

Appliance Specifications

The following flue manifold sizes are

available for different wall thicknesses:

Name

Kit No.

fits walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Natural Gas

Propane Gas

Minimum supply gas pressure

5.0 in (127 mm) W.C.

11.0 in (280 mm) W.C.

Maximum supply gas pressure

10.5 in (267 mm) W.C.

13.0 in (330 mm) W.C.

BTU/hour input

Low 10,500 High 38,400

Low 10,500 High 36,500

BTU/hour output

Low 8,400 High 30,720

Low 8,400 High 29,200

Flue Manifolds