Russound MCA-C5 User and Installation Manual

INSTALLATION GUIdE

Rack Mount Installation

To attach the rack ears, locate the five rack mount holes on each side of the

controller’s chassis. Align the holes in the rack ears with the holes in the chassis.

Insert and tighten the screws.

Wiring

Route CAT-5e cable between the keypad locations and the controller.

Terminate all CAT-5e cables with an RJ-45 connector using the T568A wiring

standard configuration. Utilize a UL/CSA approved electrical box at the keypad

(double-gang at least 32 cu. in.) and controller locations. Using connector

specific wall plates at the controller location will better organize all of the

incoming cables. Route CAT-5e wire from the electrical box to each keypad

location. Label the wires at both ends with the zone and location.

Route standard 4 conductor speaker wire to each speaker location. Each

speaker connection requires a 4-8 ohm load and will provide 40 watts per

channel. Standard 16-gauge 4-conductor stranded speaker wire can be run up

to 125 feet; 14-gauge wire can be run up to 250 feet.

+

+

Side View

Rack Ear

Front View

Rack Ear

Side View

Rack Ear

Screw Holes

/

/

/

/