Features, Options/accessories, Specifications – RayTek Raynger MX Series User Manual

Page 2: Target spot sizes and distances, Applications

Advertising
background image

25mm

@ 0m

1.0"

@ 0"

19mm

@1.15m

0.76"

@ 3'10"

286mm

@10m

11"

@ 32.8'

Temperature range

-30 to 900°C (-25 to 1600°F), MX2, MX4, MXCF
-50 to 500°C (-58 to 932°F), MXSZ

Accuracy*

±1% of reading or ±1°C (±2°F), whichever is greater

Repeatability*

±0.5% of reading or ±1°C (±2°F), whichever is greater

Response time

(95%) 250 mSec

Spectral response

8 to 14 µm, thermopile detector

Display resolution

tenth degree reading up to 900°C (0.2°F to 999.8°F)

Ambient operating range

0 to 50°C (32 to 120°F)

Relative humidity

10-95% RH noncondensing @ up to 30°C (86°F)

Storage temperature

-30 to 50°C (-25 to 122°F) without battery

Power

2 AA batteries, DC power for MX4 and MX4+

Tripod mount

1/4-20 UNC

Dimensions

200 x 170 x 50 mm (7.9 x 6.7 x 2 inches)

Weight

480 g (1 lb. 6 oz)

*only at 23°C (73°F)

MX2

MX4

MX4+

Adjustable emissivity

✓

✓

✓

On-board emissivity table

-

✓

✓

*16-point laser circle spot; meets IEC

✓

✓

✓

Class 2 & FDA Class II requirements

*Single Laser Class III

✓

-

-

Audible/visible High alarm

✓

✓

✓

Audible/visible Low alarm

✓

✓

MAX and MIN temperature

✓

✓

✓

DIF and AVG temperature

-

✓

✓

Bar graph display

✓

✓

✓

Data output: RS232 or

-

✓

✓

1 mV per degree (°C or °F)

100 points of data logging

-

✓

✓

Windows-compatible

-

-

✓

Data Graphing Software

-

-

✓

Power Supply (110 or 220V),

-

-

✓

RS232 Computer Cable, 1.5 m (60 in),
K thermocouple probe

*MX2 available with either 16-point class II, or single point class III laser sighting system.

MX2, MX4, MX4+ and MXSZ

D:S = 60:1 at Focus Point

Target Spot Sizes and Distances

R A Y N G E R M X P O R T A B L E N O N C O N T A C T T H E R M O M E T E R S

F E A T U R E S

S P E C I F I C A T I O N S

■

Windows-based Data Graphing Software*

■

Thermistor (NTC) probe

■

RS232 computer cable*

■

Portable thermal printer

■

Thermocouple K probe*

■

Calibration Certification

■

Plug-in Power Supply (110 or 220V)*

■

Soft pouch

*Standard with Raynger MX4+

O P T I O N S / A C C E S S O R I E S

The rugged, ergonomic MX has many uses:

■

check for hot spots in electrical panels, circuit
breakers, generators, and gearboxes

■

monitor supply and return registers, air stratification,
and duct leakage

■

monitor temperatures of gasoline and diesel
engine cylinders and railroad axles and bearings

■

food preparation and storage

■

Industrial predictive and preventative maintenance.

■

Checking for icing and deicing on planes
and asphalt

■

Checking for depleted refrigeration media

■

Cold storage and walk-in refrigeration applications

■

Frozen food safety and processing

■

ISO 9000 proactive maintenance programs

■

Checking for bearing failures and motor misalignment

■

Power distribution trouble shooting

■

Electrical bench work in the shop or lab

A P P L I C A T I O N S

25mm

@ 0mm

1.0"

@ 0"

6mm

@300mm

0.24"

@ 11.4"

70mm

@1000mm

2.81"

@ 40"

MXCF (Close Focus)

D:S = 50:1 at Focus Point

Raytek, the Raytek logo, and Thermalert are registered trademarks
of Raytek Corporation.
©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A
Specifications subject to change without notice. 3-1022

Worldwide Headquarters
Raytek Corporation
Santa Cruz, CA USA
Tel: 1 831 458 1110
800 866 5478 (U.S. and Canada only)
Fax: 1 831 425 4561
www.raytek.com

5710 Kenosha Street
Richmond, Illinois 60071 USA
Phone: +1 (815) 678-2211
FAX: +1 (815) 678-3961
Internet: www.watlow.com
e-mail: [email protected]

RIC-MX-0401

For Sales and Ordering Contact:

For Service and

Warranty Contact:

Your Authorized Watlow Distributor Is:

Advertising