Features, Options/accessories, Specifications – RayTek Raynger MX Series User Manual
Page 2: Target spot sizes and distances, Applications
25mm
@ 0m
1.0"
@ 0"
19mm
@1.15m
0.76"
@ 3'10"
286mm
@10m
11"
@ 32.8'
Temperature range
-30 to 900°C (-25 to 1600°F), MX2, MX4, MXCF
-50 to 500°C (-58 to 932°F), MXSZ
Accuracy*
±1% of reading or ±1°C (±2°F), whichever is greater
Repeatability*
±0.5% of reading or ±1°C (±2°F), whichever is greater
Response time
(95%) 250 mSec
Spectral response
8 to 14 µm, thermopile detector
Display resolution
tenth degree reading up to 900°C (0.2°F to 999.8°F)
Ambient operating range
0 to 50°C (32 to 120°F)
Relative humidity
10-95% RH noncondensing @ up to 30°C (86°F)
Storage temperature
-30 to 50°C (-25 to 122°F) without battery
Power
2 AA batteries, DC power for MX4 and MX4+
Tripod mount
1/4-20 UNC
Dimensions
200 x 170 x 50 mm (7.9 x 6.7 x 2 inches)
Weight
480 g (1 lb. 6 oz)
*only at 23°C (73°F)
MX2
MX4
MX4+
Adjustable emissivity
✓
✓
✓
On-board emissivity table
-
✓
✓
*16-point laser circle spot; meets IEC
✓
✓
✓
Class 2 & FDA Class II requirements
*Single Laser Class III
✓
-
-
Audible/visible High alarm
✓
✓
✓
Audible/visible Low alarm
✓
✓
MAX and MIN temperature
✓
✓
✓
DIF and AVG temperature
-
✓
✓
Bar graph display
✓
✓
✓
Data output: RS232 or
-
✓
✓
1 mV per degree (°C or °F)
100 points of data logging
-
✓
✓
Windows-compatible
-
-
✓
Data Graphing Software
-
-
✓
Power Supply (110 or 220V),
-
-
✓
RS232 Computer Cable, 1.5 m (60 in),
K thermocouple probe
*MX2 available with either 16-point class II, or single point class III laser sighting system.
MX2, MX4, MX4+ and MXSZ
D:S = 60:1 at Focus Point
Target Spot Sizes and Distances
R A Y N G E R M X P O R T A B L E N O N C O N T A C T T H E R M O M E T E R S
F E A T U R E S
S P E C I F I C A T I O N S
■
Windows-based Data Graphing Software*
■
Thermistor (NTC) probe
■
RS232 computer cable*
■
Portable thermal printer
■
Thermocouple K probe*
■
Calibration Certification
■
Plug-in Power Supply (110 or 220V)*
■
Soft pouch
*Standard with Raynger MX4+
O P T I O N S / A C C E S S O R I E S
The rugged, ergonomic MX has many uses:
■
check for hot spots in electrical panels, circuit
breakers, generators, and gearboxes
■
monitor supply and return registers, air stratification,
and duct leakage
■
monitor temperatures of gasoline and diesel
engine cylinders and railroad axles and bearings
■
food preparation and storage
■
Industrial predictive and preventative maintenance.
■
Checking for icing and deicing on planes
and asphalt
■
Checking for depleted refrigeration media
■
Cold storage and walk-in refrigeration applications
■
Frozen food safety and processing
■
ISO 9000 proactive maintenance programs
■
Checking for bearing failures and motor misalignment
■
Power distribution trouble shooting
■
Electrical bench work in the shop or lab
A P P L I C A T I O N S
25mm
@ 0mm
1.0"
@ 0"
6mm
@300mm
0.24"
@ 11.4"
70mm
@1000mm
2.81"
@ 40"
MXCF (Close Focus)
D:S = 50:1 at Focus Point
Raytek, the Raytek logo, and Thermalert are registered trademarks
of Raytek Corporation.
©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A
Specifications subject to change without notice. 3-1022
Worldwide Headquarters
Raytek Corporation
Santa Cruz, CA USA
Tel: 1 831 458 1110
800 866 5478 (U.S. and Canada only)
Fax: 1 831 425 4561
www.raytek.com
5710 Kenosha Street
Richmond, Illinois 60071 USA
Phone: +1 (815) 678-2211
FAX: +1 (815) 678-3961
Internet: www.watlow.com
e-mail: [email protected]
RIC-MX-0401
For Sales and Ordering Contact:
For Service and
Warranty Contact:
Your Authorized Watlow Distributor Is: