Rev.2.00, Oct.14.2003, page 4 of 7

Recommended Operating Conditions

Item

Symbol

Min

Max

Unit

Conditions

Supply voltage range

V

CC

3.0

5.5

V

Input voltage range

V

I

0

5.5

V

Output voltage range

V

O

0

V

CC

V

—

6

V

CC

= 3.0 to 3.6 V

I

OL

—

12

V

CC

= 4.5 to 5.5 V

—

–6

V

CC

= 3.0 to 3.6 V

Output current

I

OH

—

–12

mA

V

CC

= 4.5 to 5.5 V

0

100

V

CC

= 3.0 to 3.6 V

Input transition rise or fall rate

∆

t /

∆

v

0

20

ns / V

V

CC

= 4.5 to 5.5 V

Operating free-air temperature T

a

–40

85

°C

Note:

Unused or floating inputs must be held high or low.

Electrical Characteristic

•

Ta = –40 to 85°C

Item

Symbol V

CC

(V) *

Min

Typ

Max

Unit Test condition

3.0 to 3.6

1.5

—

—

V

IH

4.5 to 5.5

2.0

—

—

3.0 to 3.6

—

—

0.6

Input voltage

V

IL

4.5 to 5.5

—

—

0.8

V

3.3

—

0.10

—

Hysteresis voltage

V

H

5.0

—

0.15

—

V

V

T

+

– V

T

–

Min to Max

V

CC

–0.1

—

—

I

OH

= –50

µ

A

3.0

2.48

—

—

I

OH

= –6 mA

V

OH

4.5

3.8

—

—

I

OH

= –12 mA

Min to Max

—

—

0.1

I

OL

= 50

µ

A

3.0

—

—

0.44

I

OL

= 6 mA

Output voltage

V

OL

4.5

—

—

0.55

V

I

OL

= 12 mA

Input current

I

IN

0 to 5.5

—

—

±1

µ

A

V

IN

= 5.5 V or GND

Quiescent
supply current

I

CC

5.5

—

—

10

µ

A

V

IN

= V

CC

or GND,

I

O

= 0

∆

I

CC

5.5

—

—

1.5

mA

One input V

IN

= 3.4 V,

other input V

CC

or GND

Output leakage current I

OFF

0

—

—

5

µ

A

V

I

or V

O

= 0 to 5.5 V

Input capacitance

C

IN

5.0

—

3.0

—

pF

V

IN

= V

CC

or GND

Note:

For conditions shown as Min or Max, use the appropriate values under recommended operating
conditions.