Serial communications, 1 rs-232 connection and port configuration, 2 serial command syntax – Runco VX-1000d User Manual

Page 65: Table 6-1 . serial commands, Rs-232 connection and port configuration, Serial command syntax, Pre l iminar y

Advertising
background image

Runco VX-1000d Owner’s Operating Manual

53

PRE

L

IMINAR

Y

6.1
RS-232 Connection
and Port Configuration

To interface the DHD Controller with a home theater automation/control system or a PC
running terminal emulation software, connect it to your control system or PC as shown in
Figure 3-11.

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop
bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller
RS-232 port.

6.2
Serial Command
Syntax

Serial commands to the DHD Controller take the following form:

• Commands are not case-sensitive.

• For a single command that takes no parameters, type the command followed by a

carriage return; for example, to set the aspect ratio to Letterbox, type

LETTERBOX <Enter>

.

• For a single command that takes a parameter, type the command, a space or a

comma and the desired value followed by a carriage return; for example, to set the
brightness to -10, type

BRIGHTNESS -10 <Enter>

or

BRIGHTNESS,-10 <Enter>

.

• You can also send a string of multiple commands on a single line, separated by

commas. For example,

COMPOSITE,BRIGHTNESS 100,ANAMORPHIC <Enter>

switches to the Composite video input, sets the brightness to 100 and sets the aspect
ratio to Anamorphic. Command strings can be up to 255 characters long.

Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the
valid parameter ranges, or “NA” for commands that take no parameters.

When you enter a valid command, the DHD Controller executes it and acknowledges it
with a plus sign on the command line (+ >). When you enter an invalid command -- one
that is misspelled or followed by values outside the valid range for that command -- the
DHD Controller ignores it and returns a minus sign (- >).

6. Serial Communications

Table 6-1. Serial Commands

Command

Parameter

(min/max)

Value

Stored?

Description

Power On/Off Commands

OFF

NA

NA

Turns projector off

ON

NA

NA

Turns projector on

POWER

0/1

NA

Turns projector on and off

POWER?

NA

NA

Returns power status

Advertising