Roberts Gorden CTH2-125 User Manual
Page 26
CTH2-S
ERIES
I
NSTALLATION
, O
PERATION
AND
S
ERVICE
M
ANUAL
20
Step 6.3.2 Coupling and Tube Assembly (Continued)
Step 6.4 Turbulator Installation
10
'
± 1
'
(3 m ± .25 m)
Total Overall
Tube Length
7
'
6" ± 1
'
(2.3 m ± .25 m)
Model
Tube Length Minimum
CTH2-40
10' (3 m)
CTH2-60
20' (6 m)
CTH2-80
20' (6 m)
CTH2-100
30' (9 m)
CTH2-125
40' 12 m)
CTH2-150
50' (15 m)
CTH2-175
60' (18 m)
T
w
is
t
Pull String
Tab
Fold tab around outside
of tube nearest to the vent to hold turbulator
in place. Where a vent sleeve
is used, do not fold tab.
Turbulator
Section
Turbulator
Adapter
Turbulator Section
(stainless) used in CTH2-40
heaters must be in the section of
tube nearest to the burner.
Description
Part Number
Turbulator Adapter
03051503
Turbulator Section
03051504
Turbulator Section (stainless)
03051505
Tube
91409XXX
Turbulator Installation
Model
Tube Section
CTH2-40
1st 10' Section
CTH2-60
2nd 10' Section
CTH2-80
2nd 10' Section
CTH2-100
3rd 10' Section
CTH2-125
N/A
CTH2-150
N/A
CTH2-175
N/A
Turbulator must be installed in
the last standard section of
tube. Turbulator is not required
on the CTH2-125/150/175.