2. Attach mounting angles to heater jacket with 1/2"

sheet metal screws, (4 places).

3. Lower outdoor top to heater and secure with 1"

sheet metal screws.

Indoor Models

The drafthood is shipped separately and must be
installed on the heater.

Models 0260 & 0261

1. Mount drafthood on top of heater and attach with

the 4 sheet metal screws provided. Drafthood
should be positioned with the vent sensor located
on the front left side as shown.

2. Remove plastic plug from left side of heater jacket

and install plastic grommet provided.

3. Route flue sensor wire harness through the grom-

met installed in Step 2.

Fig. 4: Location of Mounting Angles

Fig. 5: Long Side of Mounting Angle Located as Shown

4. Remove door and locate wire from roll out sensor

to Hi Limit with the male/female connector.

TEMPERATURE
SENSOR

MOUNTING
SCREWS (2)

HARNESS
ASSEMBLY

CONNECT ONE
VENT SENSOR
WIRE TO THE
HIGH LIMIT WIRE

CONNECT ONE
VENT SENSOR
WIRE TO THE
ROLL-OUT
SENSOR WIRE

WIRE FROM
TRANSFORMER

ROLL-OUT
SENSOR

Fig. 6: Mounting Flue Sensor

WIRE FROM TRANSFORMER

MALE/FEMALE
WIRE TERMINAL

WIRE FROM HIGH LIMIT

ROLL OUT SENSOR

Fig. 7: Before Installation of Drafthood

WIRE FROM TRANSFORMER

CONNECT ONE VENT SENSOR WIRE
TO HIGH LIMIT WIRE

CONNECT ONE VENT SENSOR WIRE
TO ROLL OUT SENSOR WIRE

ROLL OUT SENSOR

Fig. 8: After Installation of Drafthood

5. Disconnect male/female connector and attach to

the 2 wires from drafthood vent sensor harness.