Technical data – Rinnai RHFE-1004FA User Manual

Page 58

Advertising
background image

– 56 –

TECHNICAL DATA

GAS CONVERSION SPECIFICATIONS

Burner Orifices:

The minimum inlet gas supply pressures is for the purpose of input adjustment.
Heaters may be converted from one gas to another using Rinnai conversion kits.

HI

LOW

NG

PARTS No.

1004F-2031-2-1.80

1004F-2036-2-1.95

QTY'

2

1

LPG

PARTS No.

1004F-2031-1-0.95

1004F-2036-1-1.20

QTY'

2

1

WEIGHT

DIMENSIONS

GAS RATE (BTU/h)

90 Lbs.

Width: 36 5/8"
Height: 26 3/8"
Depth: 12 3/8"

INPUT

NG

LP

LOW

10,500 10,500

HIGH

38,400 36,500

OUTPUT

NG

LP

LOW

8,400

8,400

HIGH

30,720 29,200

GAS SUPPLY PRESSURE

RHFE-1004FA-N

MODEL

GAS
TYPE

DIAMETER OF
ORIFICE(mm)

DAMPER
A-DJUSTMENT

NG

1.80

1.95

MANIFOLD DIFFERENTAL
PRESSURE (W.C.)

HI

FRONT

HI

LOW

RIGHT

LEFT

7/10

10/10

10/10

LO

3.7"W.C.

2.0"W.C.

MINIMUM
MAXIMUM

NATURAL

5.0"W.C.

10.5"W.C.

PROPANE

11.0"W.C.
13.0"W.C.

RHFE-1004FA-P

LPG

0.95

1.20

10/10

10/10

10/10

10.1"W.C.

4.3"W.C.

Advertising