Level setting the blt, 1khz test tone @ “0db – Rockford Fosgate 500.2 User Manual

Page 23

Advertising
background image

– 20 –

Level Setting the BLT

• Disconnect Speaker(s) from the amplifier

• CD Software used to set levels is a test tone of 1kHz at “0dB” or “All Bits High”

• Source Unit set to 3/4 volume (or maximum unclipped output)

• Remove BLT Cover to access

test pads and gain pots

• AC Voltmeter set to

AC Volts

• AC Voltmeter “–” connected to

RCA shield of BLT

• AC Voltmeter “+” connected to

test pad inside the BLT

• Adjust BLT Gain from

3.25 VRMS min. to 10.3 VRMS max per test pad (see chart below)

Be sure the time index reads greater than 30 seconds on source unit.

*Absence of gain overlap will reduce SPL and may not permit amplifier to reach full output power due to various CD
software.

Gain Overlap

BLT Output (AC Volts)

Performance Characteristics

+0dB*

3.25 VRMS

Best S/N Ratio, Reduced SPL

+5dB

5.8 VRMS

Good S/N Ratio & SPL

+10dB

10.3 VRMS

Best Compromise between S/N Ratio & SPL