11

When the circuit is connected as shown in figure 1.6, the switches of the emulator are set as SW2
= 1 and SW3 = 1. For details, refer to section 3.8, Setting the DIP Switches, in the SuperH

TM

Family E10A-USB Emulator User’s Manual.

1

TCK

TMS

RESET

TDI

TDO

TRST

ASEBRK
/ BRKACK

GND

GND

GND

GND

(GND)

2

3

4

5

6

7

8

9

11

10

12

13

14

TCK

TMS

TDO

TDI

TRST

ASEBRK/BRKACK

N.C.

UVCC

H-UDI port connector
(14-pin type)

All pulled-up at 4.7 k

Ω

or more

1 k

Ω

User system

RESETP

MPMD

RESETA

Reset signal

Power-on reset signal

*2

*1

VccQ_SR

SH7362

VccQ_SR = 2.85-V/1.8-V I/O power supply
VccQ_MFI = 2.85-V/1.8-V I/O power supply
VccQ = 2.85-V I/O power supply

VccQ_SR VccQ_SR VccQ_SR VccQ_SR

VccQ_SR

Level-shift
circuit

*3

Figure 1.6 Recommended Circuit for Connection between the H-UDI Port Connector and

MPU when the Emulator is in Use (14-Pin Type)

Notes: 1. Do not use /RESETP in the emulator after the user system has been activated.

When reset signals are used for debugging, use /RESETA.

2. Fix /RESETA as high level when it is not used.

3. When the voltage level of VccQ_SR (power supply for H-UDI and AUD) is 2.85 V

and that of VccQ_MFI (power supply for /RESETA) is 1.8 V, a level-shift circuit is
required as shown in the figure.