Reb-4315 operational manual, 5 reference schematic: for example – RoyalTek REB-4315 User Manual

Page 6

Advertising
background image

RoyalTek

Confidential

5

REB-4315 Operational Manual

5 Reference

schematic:

For example:

Note:

(1) Ground Planes:

These pin(8、18、20、21、22) should be connect to ground.

(2) Serial Interface:

(Ⅰ)The TX pin is the serial output data.<UART data transmit (TX)>
(Ⅲ)The RX pin is the serial input data.< UART data receive (RX)>

(3) RF_IN:

Connecting to the antenna has to be routed on the PCB. The transmission line must
to be control impedance from RF_IN pin to the antenna or antenna connector of
your choice. (Impedance 50Ω)

Recommend used Active antenna (Gain 27).

(4) Power:

Connect VCC_IN_1V8 pin to DC 1.8V. The power supply must add bypass
capacitor(10uF and 1uF).It can reduce the Noise from power supply and increase
power stability.

Shutdown

Shutdown the REB-4315 module, don’t remove the Vcc_IN_1V8 Pin, must be
use on/off pulse make it into Hibernate mode.(It’s will keep the Warm start
and Hot start function work well)


(5) nRESET:

External reset input with internal pull-up, active low.
(6) ON/OFF:

Advertising