Installing the
Lamp
To install the lamp, remove the screw holding the lamp/air filter cover in place. Then, lift
the cover up and away from the projector.
Turn the knob to open the inner lamp cooling compartment and reveal the cathode end (–)
of the lamp; see Figure 3-6.
Figure 3-6. Accessing the Lamp Cooling Compartment
➤
Xenon arc lamps are under high pressure and must be handled
with great care at all times. Lamps may explode if dropped or
mishandled.
Never open the lamp door unless you are wearing protective
clothing. Recommended protective clothing includes — but may
not be limited to — protective gloves, latex lab gloves, a
double-layer 0.040” acetate face shield, and a quilted ballistic nylon
jacket or welder’s jacket.
WARNING
(turn to
open)
Remove
Lamp/Air Filter
Cover
Lamp Cooling Compartment Door