Redring hotbox boiler – Redring L318 User Manual
Page 2

Page 2 of 13
Redring Hotbox Boiler
THE HALOGEN BOILER, L318, LP330
HALOGEN POWERED WALLMOUNTED BOILER
USER&INSTALLERS INSTRUCTIONS
PLEASE KEEP THESE INSTRUCTIONS SAFE. SHOULD YOU MOVE HOUSE, PLEASE
HAND THEM OVER TO THE NEXT OCCUPIER.
1. Introduction
The Halogen Boiler is a wall-mounted appliance, suitable for installation onto small sealed heating systems.
It incorporates all the components for sealed system requirements, these include, pressure gauge, pressure
relief valve, expansion vessel, circulating pump and manual reset overheat thermostat. A manual air vent is
also located on the appliance. There are two controls on the appliance, one adjusts the water flow
temperature, and the other is an on/off switch. A 2 m long electrical flex with integral plug enables the
appliance to be connected into a standard 13A ring main socket or via the 24 hour plug in timer supplied.
2. Technical Specification
Performance Data
L318
LP330
Electrical Input
kW
6 x 0.300
10 x 0.300
Heat Output to Water
kW
1.71
2.85
Heat Output Convection
kW
0.09
0.15
General Specification
L318
LP330
Product Catalogue Number
29-394601
29-394602
Halogen Bulb Heat Source
6 x 300W
10 x 300W
Electricity Supply
220 - 240V ~ 50 Hz 220 - 240V ~ 50 Hz
External Fuse (supplied plug)
10A
13A
Water Connections Flow
22 mm Copper
22 mm Copper
Water Connections Return
22 mm Copper
22 mm Copper
Expansion Vessel Charge
0.5 bar
0.5 bar
Minimum operating flow temp.
20°C
20°C
Maximum operating flow temp.
70°C
70°C