3. Installation

RuggedCom® RuggedSwitch®

22

RSG2288 Installation Guide Rev 108

Figure 3.22. Console Port on Display Board

Figure 3.23. RS2000 Series Console Cable

Signal Name (PC is DTE)

DB9- Female

RJ45 Male

DCD – Carrier detect

1

2

RxD – Receive data (to DTE)

2

5

TxD – Transmit data (from DTE)

3

6

DTR – Data terminal ready

4

3

GND - Signal ground

5

4

DSR – Data set ready

6

1*

RTS – Ready to send

7

8

CTS – Clear to send

8

7

RI – Ring Indicator

9

1*

Table 3.2. RS232 Over RJ45 Console Cable Pin-out

After initial configuration, the RSG2288 can be configured via a number of networked mechanisms
such as Telnet SSH, and the built-in secure web server. Consult the ROS™ User Guide for further
details.

• This port is not intended to be a permanent connection.

• Serial cable must not exceed 2m (6.5 ft) in length.

3.2.7. Ethernet Ports

3.2.7.1. RJ45 Twisted-Pair Data Ports

RS2000 series Ethernet switches are equipped with up to nine 10/100/1000BaseTX ports
that allow connection to standard CAT-5 UTP cable with RJ45 male connectors. All RS2000
series RJ45 RuggedSwitch® products feature auto-negotiation, auto-polarity, and auto-crossover
functions. The RJ45 receptacles can also accept and take advantage of screened (commonly
known as “shielded”) cabling. The figure below shows the RJ45 port pins configuration.