Additional tubing length may be added to heater. Tubing must be heat-treated, aluminized or porcelain
coated. Any additional tubing lengths are considered as vent length for length determination. Maximum
venting length for minimum heater length is 45' (13.7 m), or 22.5' (7 m) on each tube.

Table 3: Component Package Guide

Tubing Length Each Side

Core Packages (2 Required)

Model

Minimum

Hot Rolled with

Aluminum Reflector

Aluminized with

Aluminum Reflector

Aluminized with

Stainless Steel Reflector

TF-120

20' (6 m)

CP20HRS

CP20ALUM

CP20ALUMSS

TF-160

20' (6 m)

CP20HRS

CP20ALUM

CP20ALUMSS

TF-200

30' (9 m)

CP30HRS

CP30ALUM

CP30ALUMSS

TF-250

40' (12 m)

CP40HRS

CP40ALUM

CP40ALUMSS

TF-300

50' (15 m)

CP30HRS + EXP20HRS

CP30ALUM + EXP20ALUM

CP30ALUMSS + EXP20ALUMSS

TF-350

50' (15 m)

CP30HRS + EXP20HRS

CP30ALUM + EXP20ALUM

CP30ALUMSS + EXP20ALUMSS

TF-380

60' (18 m)

CP30HRS + EXP30HRS

CP30ALUM + EXP30ALUM

CP30ALUMSS + EXP30ALUMSS