Section 6 Definitions of Server Functions

Rev. 1.01 Mar. 17, 2008 Page 56 of 128

REJ10J1822-0101

6.4

Parameters

Parameters must be defined in the following format.

[parameter directive]<parameter specification>

The parameter directive is a declaration of the following parameter specification and has the form
given below.

[<type of input/output>

Δ<data type>]

<type of input/output>: Specify one of the keywords given in section 6.5, Keywords for
Input/Output.

<data type>: Specify one of the keywords given in section 6.6, Keywords for Data Types.

<parameter specification>: Define the specification of the original function.

Table 6.1 lists the available combinations of keywords although details on input/output and data
types will be described in later sections. Note, however, that REF and DESC cannot be used at the
same time.

Table 6.1 Input/Output and Data Types

Input/Output Data

Type

Option

DFLT

STR

PTR

ARY

None

9

9

9

9

REF

9

9

9

IN

DESC

9

9

9

9

None

9

9

REF

OUT

DESC

None

9

9

REF

INOUT

DESC

9: Available
⎯: Not available (RPCGEN reports an error and terminates the processing)