Raypak RHP 33 User Manual

Page 9

Advertising
background image

VIII. Summer Shutdown

If you do not plan to use the pool heat pump during the summer months, secure and protect it
as follows:

1. From the control panel, turn the control switch to

Remote

(OFF).

2. Turn the heat pump power switch to OFF.

3. Leave the valves set the way they are unless additional circulation is required. DO NOT stop

all flow through the heat pump.

4.

IMPORTANT:

Remember to reset the valves before the next heating season, or the heat pump

will not operate properly.

IX. Freeze Protection

If the pool heat pump is installed in a location subject to freezing conditions, it is important to
protect the water circuit from freezing, just as should be done for the pump and filter.

System Drain-Down

1. Turn the heat pump circuit breaker or disconnect switch to OFF.

2. From the control panel, turn the control switch to

Remote (

OFF).

3. With the pool pump OFF, close the external shutoff valves and remove the internal drain plug.

Use air pressure to remove water from the bypass assembly and heat exchanger.

4. Leave the drains open until the unit is started in the spring.

5. Cover the heat pump with a waterproof cover.

Continuous Pump Operation

It is also possible in some areas to prevent heat pump freeze damage by operating the pump
continuously during freezing weather. However, this results in significantly higher pump
operating cost. Further, if a sustained power failure occurs, the heat pump would have to be
drained anyway, or freeze damage could result.

X. Maintenance

The following maintenance procedures are designed to keep your heat pump operating at a high
level of reliability. Maintenance should be performed on a periodic basis to prevent system
failures and performance degradation.

A. Air Coil Cleaning - Efficient system operation depends on free circulation of air through the
thin and tightly-spaced fins of the evaporator coils. The evaporator should be cleaned whenever
it has a buildup of dirt or debris.

1.

WARNING

Shut OFF electricity to the heat pump.

6

Advertising