Maintenance – Regency LIBERTY L900-NG User Manual

Page 48

Advertising
background image

Regency

®

L900 Direct Vent Gas Fireplace

48

MAINTENANCE

21) Replace the valve tray and reverse steps

to re-install.

22) Turn on the gas supply and check for gas

leaks.

23) Plug in the power source.

24) Re-install the left heat shield.

25) Re-install the grate.

26) Re-install the interior brick panels.

27) Re-install the log set.

28) Re-install the glass door.

29) Check the inlet and outlet pressures.

30) Re-install the right heat shield.

31) Check operation of fl ame control.

32) Check for proper fl ame appearance.

33) Re-install the exterior brick panels.

12) Carefully remove the bottom brick panel.

Bottom Brick Panel

13) Loosen the 2 screws that hold the right

side heat shield.

14) Lift up and pull out the heat shield slightly

to clear the head screws and then hang it
on the top bracket (located directly above
the heat shield).

Bracket

Heat
Shield

15) Disconnect the inlet gas line from the
valve.

16) Disconnect the 2 connectors from the
modulating coil.

17) Disconnect the 2 red wires and 1 black
wire from the valve.

18) Remove the 16 screws that hold the valve

tray to the fi rebox and slightly pull out the
valve tray.

Wires

Valve Tray

Valve Tray Slightly Removed

Modulating Coil

Heat
Shield

19) Disconnect the black and red wires from
the solenoid valve.

20) Completely pull out the valve tray.

MAINTENANCE

18) Remove the DC Sparker wires; 1 wire for

the ignitor and 2 wires to the module box.

Advertising
This manual is related to the following products: