Powerpack from rheem-ruud, Commercial water heaters, Ab c d e – Rheem ASME 12 User Manual

Page 2: Certifications and ratings, Models numbers, Water temperature ratings dimensional information, Recovery capacities

Advertising
background image

PowerPack from Rheem-Ruud

Commercial water heaters

from Rheem-Ruud

Rheem Water Heating • 101 Bell Road, Montgomery, AL 36117-4305
800-621-5622 • [email protected] • www.rheem.com

Rheem Canada Ltd./Ltée • Water Heater Division • 128 Barton Street West, Hamilton, Ontario L8N 3P3

Not all models are available in Canada.

Printed in U.S.A

05/07 WP

RR109-2B Rev. 3

IMMERSION THERMOSTATS

Tank Capacity In Gallons

12

20

30

40

E12A-3-G

E20A-3-G

E30A-3-G

E40A-3-G

E12A-6-G

E20A-6-G

E30A-6-G

E40A-6-G

E12A-9-G

E20A-9-G

E30A-9-G

E40A-9-G

N/A

E20A-12-G

E30A-12-G

E40A-12-G

N/A

E20A-15-G

E30A-15-G

E40A-15-G

N/A

E20A-18-G

E30A-18-G

E40A-18-G

N/A

N/A

E30A-24-G

E40A-24-G

N/A

N/A

E30A-27-G

E40A-27-G

N/A

N/A

E30A-30-G

E40A-30-G

N/A

N/A

E30A-36-G

E40A-36-G

INPUT

KW

3

6

9

12

15

18

24

27

30

36

Minimum

Maximum

High

Model

Tank Capacity

Thermostat

Delivered

Delivered

Temperature

Number

Gallons

Type

Temperature

Temperature

Limit

E12A

13

Immersion

90°F

190°F

200°F

E20A

19.9

Immersion

90°F

190°F

200°F

E30A

30

Immersion

90°F

190°F

200°F

E40A

40

Immersion

90°F

190°F

200°F

MODEL

APPROX. SHIPPING

WEIGHT (LBS.)

NUMBER

A

B

C

D

E

ASME

E12A

28-1/2

19

24-1/4

14-3/4

26-1/4

135

E20A

36-1/2

19

24-1/4

14-3/4

26-1/4

160

E30A

49-1/4

19

24-1/4

14-3/4

32-1/2

192

E40A

53-3/4

21

26-3/4

16-1/2

32-1/2

228

MODELS NUMBERS

B

8"

D

A

E

3

/

4

"

T&P

4

1

/

4

"

2

1

/

2

"

SYSTEM SENTINEL

AUTOMATIC
TEMPERATURE
CONTROL

C

CERTIFICATIONS AND RATINGS

EFFICIENCY
In accordance with ANSI test procedures, these models tested below the maximum
allowable standby loss levels of current ASHRAE Standards (Part of the Federally
mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all
states including California Energy Commission (CEC).

SAFETY AND CONSTRUCTION
These products are design certified by Underwriters Laboratories (UL) to meet UL
standard 1453 as electric booster and commercial storage tank water heaters.
All models are North Carolina and Massachusetts code compliant.

CERTIFIED FOR A 160 PSI MAXIMUM WORKING PRESSURE.

ASME CONSTRUCTION
Standard on E12A, E20A, E30A, and E40A models.

In keeping with its policy of continuous progress and product improvement,
Rheem-Ruud reserves the right to make changes without notice.

®

WATER TEMPERATURE RATINGS

DIMENSIONAL INFORMATION

(All dimensions shown in inches.)

INPUT

EQUIVALENT

40°F

60°F

80°F

100°F

120°F

140°F

KW

BTU/HR.

3

10,236

31

21

16

12

10

9

6

20,473

62

41

31

25

21

18

9

30,709

93

62

47

37

31

27

12

40,946

124

83

62

50

41

35

15

51,183

155

103

78

62

52

44

18

61,420

186

124

93

74

62

53

24

81,893

248

165

124

99

83

71

27

92,129

279

186

140

112

93

80

30

102,366

310

207

155

124

103

89

36

122,839

372

248

186

149

124

106

RECOVERY CAPACITIES

(Recovery in U.S. gallons/Hr. (GPH) at various temperature rises)

Advertising