SECTION 14: R

EPLACEMENT

P

ARTS

35

14.4 Heat Exchanger

The heat exchanger consists of a four-pass design with 1.75" outer diameter [409 stainless steel] tube. The
tube plates are made of [aluminized steel] [409 stainless steel]. The tube supports are made of
[galvannealed steel] [409 stainless steel].

14.5 Flue Blower

IT IS IMPORTANT THAT ONLY THE CORRECT FLUE BLOWER SPECIFIED FOR EACH MODEL TYPE
IS USED WHEN REPLACING THESE ITEMS.
Carry out a start-up after working on or changing a flue blower. See Page 24, Section 11.

MODEL

UHD[X][S][R]

150 - 175

UHD[X][S][R]

200 - 300

UHD[X][S][R]

350 - 400

Flue Blower P/N

90710405

90710403

90710402

Remove screws securing
outlet flange to the flue
adapter.

Refit in reverse order.

Remove screws securing flue
blower mounting plate to vent
box.

Remove screws securing
mounting plate to blower.

Refit in reverse.

Use new gaskets.

Ensure sealed joints.

Ensure mounting plate orifice
is clear and not obstructed.