Dynamixel dx-series – Robotis Dynamixel DX-117 User Manual

Page 13

Advertising
background image

12

DYNAMIXEL

DX-Series

Control Table

The Control Table consists of data for conditions and movement of the Dynamixel. By

writing the values in the control table, you can move the Dynamixel and detect the

condition of the Dynamixel.

RAM and EEPROM

The data values for the RAM Area will be set to the default initial values on power on.

The data values for the EEPROM Area are non-volatile and will be available next power

on.

Initial Value

The Initial Value column of the control table shows the Factory Default Values for the

case of EEPROM Area Data. For the RAM Area Data, the initial value column gives the

power on data values.

Please note the following meanings for data assigned to each address in the control

table.

Address 0x00,0x01

Model Number

. In the case of the DX-116, the value is 0X0074(116).

Address 0x02

Firmware Version

.

Address 0x03

ID

. Unique ID number to identify the Dynamixel. Different ID’s are required to be

assigned to “linked” Dynamixels.

Address 0x04

Baud Rate.

Determines the Communication Speed. The Calculation method is:

Speed(BPS) = 2000000/(Address4+1)

Note

A maximum Baud Rate error of 3% is within the UART communication tolerance.

Data Value as per Major Baud Rate

Adress4

BPS Set

Target BPS

Error

1

1000000.0

1000000.0

0.000%

3

500000.0

500000.0

0.000%

4

400000.0

400000.0

0.000%

7

250000.0

250000.0

0.000%

9

200000.0

200000.0

0.000%

16

117647.1

115200.0

-2.124%

34

57142.9

57600.0

0.794%

103

19230.8

19200.0

-0.160%

207

9615.4

9600.0

-0.160%