Oregon Scientific JUMBO BAR289 User Manual

Page 6

Advertising
background image

5

EN

GETTING STARTED

BATTERIES

Batteries are supplied with this product:

Main unit

4 x UM-3 (AA) 1.5V

Remote control

2 x UM-4 (AAA) 1.5V

Remote sensor

2 x UM-3 (AA) 1.5V

Insert batteries before first use, matching the polarity
as shown in the battery compartment. For best results,
install batteries in the remote sensor before the main
unit. Press RESET after each battery change.

To install the main unit batteries:

To install the remote control batteries:

NOTE

UNIT

LOCATION

Main

Clock / Alarm / Calendar Area

Remote Sensor

Outdoor Temperature Area

REMOTE SENSOR (RTHR328N)

This product is shipped with the RTHR328N Remote
Sensor. The main unit can collect data from up to
5 sensors.

The THGR328N and THR228N sensors are also
compatible with this weather station. (Additional sensors
are sold separately. Contact your local stockist for more
information.)

The RTHR328N sensor collects temperature readings
and signals from official time-keeping organizations for
the radio-controlled clock.

Do not use rechargeable batteries.

shows when batteries are low.

It is recommended that you use alkaline

batteries with this product for longer performance.

NOTE

SENSOR SET UP

1. Open the battery compartment with a small Phillips

screwdriver and insert the batteries matching the
polarity (+ and -) as shown below.

2. Set the channel by pressing the CHANNEL button

to the required number. If you are using more than
one sensor, select a different channel for each
sensor.

3. Slide the EU / UK switch to the setting which best

suits your location.

4. Press RESET.

5. Place the sensor near the main unit.

6. Press SEARCH to manually initiate signal sending

between the sensor and the main unit. The reception
icon on the main unit will blink for approximately
3 minutes while it is searching for the sensor. (Refer
to the "Sensor Data Transmission" section for more
information.)

7. Press the

°C / °F button to select the setting you want.

8. Close the remote sensor battery compartment.

9. Secure the sensor in the desired location using the

wall mount or table stand.

To fold out the stand:

1

2

For best results:

Insert the batteries and select the unit, channel, and
radio signal format before you mount the sensor.

Place the sensor out of direct sunlight and moisture.

Do not place the sensor more than 30 metres
(100 feet) from the main (indoor) unit.

Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls,
and furniture.

Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.

Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.

The transmission range may vary and is subject

to the receiving range of the main unit.

You may need to experiment with various locations to
get the best results.

NOTE

BAR289 ENG R7 OP

8/20/04, 11:00 PM

5

Black

Advertising