2) install module in chassis and connect cables, 3) configure module via command line interface, Dip-switch bank 2 – Omnitron Systems Technology Plug-in Module iConverter 2FXM User Manual

Page 2: Converter

Advertising
background image

installed management modules to the RIGHT “SL” position to enable Slave-Only
mode.

SW5, SW6, SW7, SW8 - RESERVED

These DIP-switches are for factory use only and must always remain in the LEFT
position (factory default).

2) INSTALL MODULE IN CHASSIS AND CONNECT CABLES

a. Carefully slide the module into an open slot in the chassis. Align the module with

the installation guides and ensure that the module is firmly seated against the
backplane. Secure the module by fastening the front panel thumbscrew (push in
and turn clockwise to tighten) to the chassis front. Verify the “Pwr” LED is ON
(indicating the chassis is powered).

b. Insert the SFP Fiber transceivers into the Port 1 and Port 2 SFP receptacles on the

2FXM.

NOTE: The release latch of the SFP Fiber transceiver must be in the closed
position before insertion.

d. Connect an appropriate multimode or single-mode fiber cable to the SFP fiber

ports of the installed module. It is important to ensure that the transmit (TX) is
attached to the receive side of the device at the other end and the receive (RX) is
attached to the transmit side. Single-fiber (SF) media converter models operate in
pairs. The TX wavelength must match the RX wavelength at the other end and the
RX wavelength must match the TX wavelength at the other end.

NOTE: In order to support Remote OAM Management Mode, Port 1 of the
2FXM must be connected to the Port 1 on the 2FXM or link partner.

3) CONFIGURE MODULE VIA COMMAND LINE INTERFACE

To access the Command Line Interface (CLI), connect the 2FXM RS-232 Console Port
to the COM port of a computer equipped with terminal emulation software such as
HyperTerminal. The Console Port (DCE) is a mini DIN-6 female connector which can
be changed to a DB-9 connector with the included adapter. The 2FXM Console Port is
a standard asynchronous serial interface.

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect
To:” window. Set the serial port to the following:

Bits Per Second

57,600

Stop Bits

1

Data Bits

8

Parity

NONE

Hardware Flow Control

NONE

Once connected, press <ENTER> to bring up a command line prompt on the attached
PC. A new 2FXM module does not have a password, and will skip the Password
Entry
screen and go straight to the Management Options screen. If a password has
been set, the Password Entry screen will be displayed. Type the password and press
<ENTER>, the 2FXM will respond with the Management Options screen:

SW3 AND SW4 - RESERVED

These DIP-switches are for factory use only and must always remain in the LEFT
(factory default) position.

SW5 - FIBER PORT 2 FULL/HALF DUPLEX

Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports
Half-Duplex. Setting this DIP-switch to Full-Duplex “FDX” facilitates a connection that
supports Full-Duplex operation.

SW6, SW7, SW8 - LINK MODES

The module supports multiple link modes for fault detection and isolation. Link Segment
should be used for the initial installation of the module. Once installed and operational,
the link mode can be modified.

Switch

Left

(Factory Default)

Right

SW6

SW7

SW8

Link Mode Selection

SW1 Off:

Pause Disable

PAUS:
Pause Enable

Left

Left

Left Link Segment (LS)

(Factory Default)

SW2 FDX:

Fiber Port 1Full-Duplex

HDX:
Fiber Port 1Half-Duplex

Right

Left

Left Link Propagate (LP)

SW3

Reserved

Reserved

Left

Right

Left Remote Fault Detect + Link

Segment (RFD + LS)

SW4

Reserved

Reserved

Right Right

Left Remote Fault Detect + Link

Propagate (RFD + LP)

SW5 FDX:

Fiber Port 2 Full-Duplex

HDX:
Fiber Port 2Half-Duplex

Left

Left

Right Symmetrical Fault Detect (SFD)

SW6

See Link Mode Selection

Right

Left

Right Illegal Setting

SW7

Left

Right

Right Illegal Setting

SW8

Right Right

Right Illegal Setting

Figure B: DIP-Switch Bank 1

DIP-SWITCH BANK 2

SW1, SW2 - BACKPLANE ENABLE

When the DIP-switch is in the LEFT “DS” position (factory default), the Backplane Port
of the 2FXM is isolated from the chassis’ Ethernet Backplane. When the DIP-switch
is in the RIGHT “EN” position, the Backplane Port is enabled. This allows Ethernet
Backplane connectivity to an adjacent module via the chassis Backplane Link “A” or
“B” depending on the switch setting.

SW4 - MASTER/SLAVE

When the 2FXM module is installed
in a chassis with an

i

Converter

Network Management Module
(NMM), set DIP-switch to the LEFT
“M/SL” position (factory default).
The assignment of mastership is
automatically negotiated by the
installed management modules. To
designate the 2FXM module as the
master of the chassis, set the DIP-
switch to the LEFT “M/SL” position,
and set the DIP-switch of the other

Switch

Left

(Factory Default)

Right

SW1

A-DS: Disabled

Backplane Port A

A-EN: Enabled

Backplane Port A

SW2

B-DS: Disabled
Backplane Port B

B-EN: Enabled
Backplane Port B

SW3

Reserved

Reserved

SW4

M/SL:
Auto Select

SL:
Slave-Mode Only

SW5 - SW8 Reserved

Reserved

Figure C: DIP-Switch Bank 2