Transmission Distance Specifications

Recommended Combinations

Note: 1. The specifications take fluctuations in ambient temperature and slight differences between products into account.

2. The read distance and write distance are the same.
3. Sensor Installation Conditions

V600-HS51:When flush-mounted in iron

Axial offset from the Data Carrier: ±2.0 mm

V600-HS61:

When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±2.0 mm

V600-HS63:

When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±10.0 mm

V600-HS67:

When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±10.0 mm

4. Data Carrier Installation Conditions

V600-D23P53/-P54: When flush-mounted in iron

V600-D23P55/-P66N/-P66SP/-P71/-P72: When surface-mounted on resin (no metal on the backside)

V600-D23P61: When surface-mounted on metal (ferrous)

V600-D8KR12/-13/-04: When surface-mounted on metal (ferrous)

V600-D2KR16: When the Data Carrier attached to the holder is mounted on a metal (ferrous) surface

5. The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces.
6. The Data Carrier is stationary.

Model

V600-HS51

V600-HS61

V600-HS63

V600-HS67

Shape

Item

Transmission frequency

530 kHz

Ambient temperature

−10 to 60°C

−10 to 70°C

Storage temperature

−25 to 75°C

Ambient humidity

35% to 95%

Insulation resistance

50 M

Ω (at 500 VDC) between cable terminal and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between cable terminal and case (leakage current: 1 mA max.)

Degree of protection

IEC60529: IP67

Vibration resistance

Destruction: 10 to 2,000 Hz, 3-mm double amplitude, with
2 sweeps of 15 min each in 3 directions

Destruction: 10 to 500 Hz, 2-mm double amplitude, with 3
sweeps of 11 min each in 3 directions

Shock resistance

Destruction: 981 m/s

2

, 3 times each in 3 directions (18

times total)

Destruction: 490 m/s

2

, 3 times each in 3 directions (18

times total)

Cable length

2 m (fixed)

Wireless transmission
error direction

16-bit CRC (Cyclic Redundancy Check) in both directions

Indicator

---

Power: green

Weight

Approx. 70 g

Approx. 190 g

Approx. 540 g

Data Carrier

Amplifier

V600-HAR91/-HAR81/-HAM91/-HAM81/-HAR92

Sensor

V600-HS51

V600-HS61

V600-HS63

V600-HS67

Memory
EEPROM
(Battery-
less type)

V600-D23P53

0.5 to 3.0 mm

0.5 to 3.0 mm

---

---

V600-D23P54

0.5 to 5.0 mm

0.5 to 5.5 mm

---

---

V600-D23P55

0.5 to 7.0 mm

0.5 to 7.0 mm

0.5 to 9.5 mm

---

V600-D23P61

0.5 to 8.0 mm

0.5 to 9.0 mm

2 to 16 mm

---

V600-D23P66N

---

---

5 to 30 mm

5 to 35 mm

V600-D23P66SP

---

---

5 to 25 mm

5 to 30 mm

V600-D23P71

---

---

5 to 35 mm

10 to 70 mm

V600-D23P72

---

0.5 to 18 mm

5 to 35 mm

10 to 50 mm

Memory
SRAM
(Built-in-
battery
type)

V600-D8KR12

5 to 15 mm

5 to 18 mm

5 to 45 mm

10 to 60 mm

V600-D8KR13

---

---

10 to 30 mm

10 to 40 mm

V600-D8KR04

---

---

10 to 65 mm

10 to 100 mm

V600-D2KR16

---

---

2 to 15 mm

---