Oregon Scientific EMR201 User Manual

Reset c/ f

Advertising
background image

OVERVIEW

FRONT VIEW

1. Remote sensor reception indicator
2. Outdoor temperature
3. Indoor temperature
4. Ice alert LED indicator

BACK VIEW

1. °C / °F: Select temperature unit
2. RESET: Reset unit to default settings

REMOTE SENSOR

1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole
5. CHANNEL switch

GETTING STARTED

INSERT BATTERIES

1. Remove the battery compartment.
2. Insert the batteries, matching the polarities (see

FIG 2).

3. Press RESET after each battery change.

Wireless Indoor and

Outdoor Thermometer

with LED Ice Alert

Model: EMR201

USER MANUAL

4

2

3

1

T E M P

T E M P

IN

OUT

���������

RESET

C/ F

2

1

REMOTE SENSOR

To set up the sensor:
1. Open the battery compartment (see FIG 3).
2. Select channel 1 then press RESET.
3. Close the battery door.
4. Place the sensor within 30 m (98 ft) of the main

unit using the table stand or wall mount.

TIP Ideal placements for the sensor would be in any
location on the exterior of the home at a height of
not more than 5 ft and which can shield it from direct
sunlight or wet conditions for an accurate reading.

NOTE Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures
below freezing.

SENSOR DATA TRANSMISSION

To search for a sensor:
Reset the unit.

The sensor reception icon in the remote sensor area
shows the status:

TIP The transmission range may vary depending
on many factors. You may need to experiment with
various locations to get the best results.

ICE WARNING

If the channel 1 sensor falls between 3°C to -2 °C
(37°F to 28°F), LED indicator will flash, and will stop
flashing once the temperature is out of this range.

RESET

Press RESET to return to the default settings.

PRECAUTIONS

• Do not subject the unit to excessive force,

shock, dust, temperature or humidity.

• Do not cover the ventilation holes with any items

such as newspapers, curtains etc.

• Do not immerse the unit in water. If you spill

liquid over it, dry it immediately with a soft,

lint-free cloth.

• Do not clean the unit with abrasive or corrosive

materials.

• Do not tamper with the unit’s internal

components. This invalidates the warranty.

• Only use fresh batteries. Do not mix new and

old batteries.

• Images shown in this manual may differ from

the actual display.

• When disposing of this product, ensure it is

collected separately for special treatment.

LOCATION

MEANING

Indoor temperature
area
Outdoor temperature
area

Main unit batteries low

Sensor batteries low

ICON

DESCRIPTION

Main unit is searching
for sensor(s).
A channel has been
found.
The sensor cannot be
found.

OUT

OUT

OUT

OUT

OUT

OUT

OUT

• Placement of this product on certain types

of wood may result in damage to its finish for
which Oregon Scientific will not be responsible.

Consult the furniture manufacturer’s care

instructions for information.

• The contents of this manual may not be

reproduced without the permission of the

manufacturer.

• Do not dispose old batteries as unsorted

municipal waste. Collection of such waste

separately for special treatment is necessary.

• Please note that some units are equipped with

a battery safety strip. Remove the strip from the
battery compartment before first use.

NOTE The technical specifications for this product
and the contents of the user manual are subject to
change without notice.

SPECIFICATIONS

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to
learn more about Oregon Scientific products. If
you’re in the US and would like to contact our
Customer Care department directly, please visit:
www2.oregonscientific.com/service/support
OR
Call 1-800-853-8883.

For international inquiries, please visit:
www2.oregonscientific.com/about/international

FCC STATEMENT

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received, including interference that may cause
undesired operation.

WARNING Changes or modifications not expressly
approved by the party responsible for compliance
could void the user’s authority to operate the
equipment.

NOTE This equipment has been tested and found
to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection
against harmful interference in a residential
installation.

This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one
or more of the following measures:

TYPE

DESCRIPTION

MAIN UNIT

L x W x H

241 g (8.5 oz) without battery

66 x 27.5 x 87.5 mm
(2.59 x 1.08 x 3.44 in)

Weight

Temperature range -5°C to 50°C (23°F to 122°F)

Resolution

0.1°C (0.2°F)

Signal frequency

433 MHz

Humidity range

25% - 95%

Humidity resolution 1%

Power

2 x UM-4 (AAA)
1.5 V batteries

REMOTE UNIT (THN132N)

L x W x H

96 x 50 x 22 mm
(3.78 x 1.97 x 0.87 in)

Weight

62 g (2.22 ounces)

Transmission range 30 m (98 ft) unobstructed

Temperature range -20°C to 60°C (-4°F to 140°F)

Power

1 x UM-3 (AA) 1.5 V batteries

· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment

and receiver.

· Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
· Consult the dealer or an experienced radio / TV

technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as
contact for support or sales. Please call our
customer service number (listed on our website at
www.oregonscientific.com, or on the warranty card
for this product) for all inquiries instead.

We
Name:

Oregon Scientific, Inc.

Address:

19861 SW 95th Ave.,Tualatin,

Oregon 97062 USA

Telephone No.:

1-800-853-8883

declare that the product
Product No.:

EMR201

Product Name:

Wireless Indoor and Outdoor

Thermometer with LED Ice

Alert

Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,

Phase 1,41 Man Yue St.,

Hung Hom, Kowloon,

Hong Kong

is in conformity with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference
received, including interference that may cause
undesired operation.

© 2007 Oregon Scientific. All rights reserved.

P/N: 086L005000-011

2

3

4
5

1

Advertising