2.3.7 Using the Alarm Functions

The thermometer provides audible and visible alarm
indications.

• To set the high alarm value:

1. Pull the trigger. Then press and hold the

key until

the High Alarm Display Mode (HAL) appears.

2. Press the

key to increment the high alarm value. Press

the

key to decrement the high alarm value.

3. Press the

key to enable the high alarm function. The

icon appears.

If the temperature exceeds the high alarm setpoint,

you will hear a beep and the

icon on the

display flashes.

4. To disable the high alarm, press the

key again,

and the

icon disappears.

If you are not in High Alarm Display Mode (HAL) when

the high alarm goes off, you must press the

key to

get into the High Alarm Display Mode. Then press the

key to disable the high alarm.

The high alarm setpoint does not change when the
thermometer is turned off. However, when the
batteries are replaced, it is reset to the default value
as follows:

OS530HR:

250°F

OS531:

750°F

OS530L, OS532, OS533:

1000°F

OS534:

1600°F

OS523:

2500°F

OS524:

4500°F

NOTE

NOTE

°F

HAL

2-15

Using the Handheld Infrared Thermometer