DISCONNECTED SIGNALS

If without obvious reason the display for the main unit goes blank
or “

” are displayed, press and hold [CHANNEL] to enforce an

immediate search.

If that fails, check:

- All weather instruments are still in place.

- The batteries of the main unit and individual weather instruments

are still good. Replace them if necessary. Press and hold
[CHANNEL] to enforce an immediate search afterwards.

- The transmission is within range and path is cleared of obstacles

and interference. Shorten the distance if necessary.

Then press and hold [CHANNEL] again. The main unit will start
searching for all previously locked weather instruments.

If you want to add an new sensor, press the reset button on the new
sensor and then press channel to enforce the main unit to search.

Note: 1. Do not reset the sensors after the main unit has locked

those sensors, otherwise the main unit will no longer
receive the signal from those sensors.

2. If you have disconnected signals, you cannot clear the

memory.

THE RESET BUTTON

This button is only used when the system is operating in an
unfavorable way or malfunctioning. Use a blunt stylus to hold
down the button. The main unit will return to all default settings
and start searching for signals again.

Before resetting the main unit, you should do the same for all
weather instruments to ensure correct transmission and reception
of signals. Then press reset on the main unit.

MAINTENANCE

When handled properly, this unit is engineered to give you years
of satisfactory service. Here are a few product care instructions:

1. Do not immerse the unit in water. If the unit comes in contact

with water, dry it immediately with a soft lint-free cloth.

2. Do not clean the unit with abrasive or corrosive materials.

Abrasive cleaning agents may scratch the plastic parts and
corrode the electronic circuit.

3. Do not subject the unit to excessive: force, shock, dust,

temperature, or humidity. Such treatment may result in
malfunction, a shorter electronic life span, damaged batteries, or
distorted parts.

4. Do not tamper with the unit’s internal components. Doing so

will terminate the unit’s warranty and may cause damage. The
unit contains no user-serviceable parts.

5. Only use new batteries as specified in this instruction manual.

Do not mix new and old batteries as the old batteries may leak.

6. Read this instruction manual thoroughly before operating the unit.

SPECIFICATIONS

Temperature

Proposed Operating Range : Indoor ..... -5°C to 50°C
( 23°F to 122°F )

: Outoor ..... -20°C to 60°C

( -4°F to 140°F )

Resolution

: 0.1°C (0.2°F)

(indoor and outdoor)

Relative Humidity

Measuring Range

: 2 to 98% RH

(indoor and outdoor)

Resolution

: 1% RH

(indoor and outdoor)

Dew Point Temperature

Measuring Range

: Indoor ..... 0°C to 49°C
( 32°F to 120.2°F )

: Outoor ..... -10°C to 60°C
( 14°F to 140°F )

Resolution

: 1°C (2°F)

(indoor and outdoor)

Barometric Pressure / Trend

Measuring Range

: 795 to 1050 mb

(23.48 to 31.01 inHg)

Resolution

: 1 mb (0.03 inHg)

Wind Speed

Measuring Range

: 0 to 56 m/s (0 to 125.3 mph)

Resolution

: 0.2 m/s (0.4 mph) (typical)

Wind Direction

Measuring Range

: 0° to 359° (Degrees)

Digital Resolution

: 1° (typical)

Graphical Resolution

: 10°

Wind Chill Temperature

Measuring Range

: -52°C to 60°C (-61.6°F to 140°F)

Resolution

: 1°C (2°F)

Rainfall

Daily and Cumulative

: 0 to 9999 mm (0 to 393.7 in)

Measuring Range

Rainfall Rate

: 0 to 999 mm/hr (0 to 39.37 in/hr)

Measuring Range

Daily and Cumulative

: 1 mm (0.04 inch)

Resolution

Rainfall Rate Resolution

: 1mm/hr (0.04 m/h) typical

WMR968 :

Weight

: 505 g

Dimension

: 204 (L) x 139 (W) x 39 (H)

Power

: 12V AC / DV adapter

Power backup

: 4 x UM3 - “AA” size alkaline battery

WGR968 :

Weight

: 430 g

Dimension

: 295 (L) x 116.5 (W) x 550 (H)

Power

: solar cell (STR918)