Zn=x — store phone number, Bn — transmit break, Gn — modem-to-modem flow control – Ositech comm Trumpcard Data/Fax Modem User Manual

Page 59: Kn — break control, Result codes, Examples

Advertising
background image

User’s Guide and Reference

4 - 27

Modem Command Reference

&Zn=x — Store Phone Number

Parameters

n = 0, 1, 2, or 3, x = dial string

Default

none

Stores a 36-digit dial string (x) in the specified entry (n) for later dialling.
(See DSn command.)

\Bn — Transmit Break

Parameters

1 through 9 (If n = 0, the default value is used; if n is

greater than 9, 9 is used.)

Default

3

When this command is entered during a non-error correction connection,
the modem sends a break signal to the remote modem. The length of the
break is 100 times the n parameter value in milliseconds. If this command
is entered during an error-correcting connection, the break will be sent via
the error-correcting protocol giving no indication of length.

Result Codes

NO CARRIER

If not connected

\Gn — Modem-to-Modem Flow Control

Parameters

0 or 1

Default

0

The command applies in non-error correction mode; the modem enables
or disables the generation or recognition of modem-to-modem XON/XOFF
flow control.

Examples

AT\G0

Disables modem-to-modem flow control

AT\G1

Enables modem-to-modem flow control

\Kn — Break Control

Parameters

0 through 5 (If n is greater than 5, 5 is used.)

Default

5

Determines what the modem will do when a BREAK is received from the
communications software or the remote modem. During error correction
mode, the remote modem's BREAK control setting determines how the
local modem will handle the BREAK.