13.3. Vibration Strength

No malfunction occurred after the following vibration test.

Vibration Test: Increase the frequency of the vibration from 10 Hz to 100 Hz with
accelerated velocity 19.6m/s

2

(2G) for 60 minutes in non-operating state. Repeat this

routine in each X, Y, Z direction once for 60 minutes each.

13.4. Static Electricity

Air discharge:

10 kV Max. (No malfunction)
15 kV Max. (No destruction)

Measurement environment:

Use electrostatic testing device compliant with IEC 61000-4-2

Discharge resistance:

330 Ω

Capacitor charging:

150 pF

13.5. Dust and Drip Proof

IEC IP42

13.6. Cable Strength

13.6.1.

Cable Pulling Test

No malfunction occurred after the following pulling test.
Pulling test: Fix the scanner and pull the cable with the force of 2.5 kg (24.5N) for
1 second. Repeat 20 times.

13.6.2.

Cable Tail Bending Test

No malfunction occurred after the following bending test.
Bending test: Fix the scanner and attach a weight of 500 grams (4.9N); swing the
cable back and forth at an angle of 90°. Repeat it 1,000,000 times.

Figure 27: Cable tail bending test