3.3.6 Interrupt Polarity Control Register


(Read/Write): wBase+0x2A
Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0 0 0 0 INV3

INV2

INV1

INV0

Note. Refer to Sec. 3.1 for more information about wBase.

INV0=1Æ select the non-inverted signal from PC0
INV0=0Æ select the inverted signal from PC0

outportb(wBase+0x2a,0x0f); /* select the non-inverted input PC0/1/2/3 */
outportb(wBase+0x2a,0x00); /* select the inverted input of PC0/1/2/3 */

outportb(wBase+0x2a,0x0e); /* select the inverted input of PC0 */

/* select the non-inverted input PC1/2/3 */


outportb(wBase+0x2a,0x0c); /* select the inverted input of PC0/1 */

/* select the non-inverted input PC2/3 */

Refer to Sec. 2.4 for more information.
Refer to DEMO5.C for more information.

3.3.7 I/O Selection Control Register


(Write): wBase+0xcc
Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0 0 0 0 0 Port2

Port1

Port0

Note. Refer to Sec. 3.1 for more information about wBase.

Port? = 1Æ this port is used as a D/O port
Port? = 0Æ this port is used as a D/I port

outportb(wBase+0xcc,0x00); /* configure Port0/1/2 as D/I port */

outportb(wBase+0xcc,0x04); /* configure Port0/1 as D/I port */
/* configure Port2 as D/O port */