(B) Open the original cover and rotate the roller rotating knob to remove the

misfed original from the exit area. If the misfed original cannot be easily
removed, proceed to (C).

(C) If the original does not move easily into the exit area, remove it in the

direction of the arrow while rotating the knob.

A number may appear in the display after a minus sign, indicating the
number of the originals that must be returned to the original feeder tray.
Open and close the SPF to clear the SPF misfeed

(

)

indicator and

then clear the misfeed and return the required number of originals. Then
press the start (

) key to resume copying.