Msi/plessey options – Oregon PowerScan Handheld Laser Scanner User Manual

Page 130

Advertising
background image

124

PowerScan

®

Scanner

MSI/Plessey Options

The MSI/Plessey symbology has the following programmable
features:

Check Digit

Label Length Format

Read Verification

Check Digit

Check Digit calculates the Check Digit(s) to verify the labels contents
have been read correctly. If you enable this feature, your bar codes
must include a Check Digit(s). You may also choose to transmit or not
transmit the Check Digit(s).

Check Digit Calculation

- enables or disables calculation of

the Check Digit(s).

Transmit Check Digit

- enables or disables transmission of

MSI/Plessey Check Digit(s).

Number of Check Digits

- specifies either one or two Check

Digits.

Label Length

Format

Label length format permits the selection between variable length or
fixed length formats. For best performance it is recomended to use the
Fixed Length settings when your application requires only one or two
label lengths.

Variable Length Format

- directs the scanner to read all labels from the

minimum label length to 16. Set Minimum Length as high as your
application allows.

Minimum Label Length

- selects the minimum label length

that the scanner will recognize. The minimum label length for
this symbology must be between 04 and 16.

Fixed Length Format

- directs the scanner to read only one or two label

lengths.

If you select fixed length format, there are three bar code labels for pro-
gramming your scanner to read either one or two fixed lengths. The
labels are:

Set First Fixed Length

- instructs the scanner that the next two

programming labels scanned will define the first fixed label
length. This setting must be between 04 and 16 characters.

Advertising