Oceanic Dive Computer Pro Plus 2 User Manual

Page 69

Advertising
background image

69

To access the Time to Fly Countdown (while in Surface Mode)

• Press the Left (Advance) button 2 times.
• The Time to Fly counter (Fig. 75) begins counting down 10

minutes after surfacing from a dive (after the Transition
Period) displaying the word 'FLY' and a countdown that
begins at 23:50 (hr:min) and counts down to 0:00
(hr:min).

• If a Violation occurred during the dive a single dash ( - )

will appear instead of the letters FLY.

• The unit will revert to Surface Mode after 2 minutes, unless

the Left (Advance) button is pressed to access the Desat
Time Countdown.

To access the Time to Desaturation Countdown

(while in Surface Mode)

• Press the Left (Advance) button 3 times.
• The unit will revert to Surface Mode after 2 minutes, unless

the Left (Advance) button is pressed to access the Log
Mode.

• If a Violation occurred during the dive, Desaturation Time

will not be displayed.

The Time to Desaturate counter (Fig. 76) provides calculated
time for tissue desaturation at sea level. The countdown starts
10 minutes after surfacing at 23:50 (hr:min) maximum and
counts down to 0:00 (hr:min).

Fig. 75 - Time to Fly

Fig. 76 - Time to Desaturate

ATR

O

2

N

2

ATR

O

2

N

2