27. Transmitting Error Indications (Trigger Enabled only)

Page 50

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

,Z7,

5A

Wait 30 mS after trigger pulse

before sending error code

,5A,

5B

Wait 80 mS after trigger pulse

before sending error code

,5B,

5C

Wait 130 mS after trigger pulse

before sending error code

,5C,

5D

Wait 220 mS after trigger pulse

before sending error code

,5D,

5E

Do not transmit error code

,5E, B

5F

Transmit “BR”<CR> for bad read

or no read

,5F,

5G

Transmit <STX>“>”<ETX>

for bad read;

<STX>“?”<ETX> for no read

,5G,

5H

Transmit “>” <CR> for bad read

Transmit “?” <CR> for no read

,5H,

5I

Transmit “CAN”<CR> for bad

read or no read

,5I,

5J

Transmit <STX>“CAN”<ETX> for

bad read or no read

,5J,

5K

Transmit <STX><CAN><CR>

<LF> for bad read or no read

,5K,

5L

Transmit <STX><CAN><CR>

for bad read or no read

,5L,

5M

Transmit "BR"<CR><LF>

for bad read or no read

,5M,