Sylvania 066136 User Manual

G-temp heater, Description, Specifications

Advertising
background image

OPERATING INSTRUCTIONS

OSRAM

8/12/00

SYLVANIA

Process Heat

131 Portsmouth Ave. Exeter, NH 03833 USA Tel: 800-258-8290 Fax: 603-772-1072

1

G-TEMP HEATER

065253, 066136, 070282

FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Description

!

Compact, efficient heater with integrated temperature and power controller for heating air or inert gases to
1300°F (700°C). A thermal sensor in the control box turns the heater power off if airflow is lost, or the inlet air
temperature is too high. A built-in airflow damper controls airflow, and control potentiometer controls
temperature. If operated correctly, the heater will operate continuously for 5000 hours or longer.

Specifications

MAXIMUM INLET PRESSURE

2 PSI (.14 BAR)

MAXIMUM INLET AIR TEMPERATURE

100°F (38°C)

MAXIMUM EXIT AIR TEMPERATURE

1300°F (760°C)

MODEL
NUMBER

MAXIMUM
WATTAGE

SUPPLY
VOLTAGE

AMP
RATING

REPLACEMENT
ELEMENT
NUMBER

066136

1500

120 - 60 Hz

13

066137

065253

3000

230 - 60 Hz

15

065335

070282

3000

230 - 50 Hz

15

065335

Safety

!

SHOCK HAZARD Only qualified individuals should install this heater and related controls. Follow all applicable
electrical codes and use proper wiring.

Advertising
This manual is related to the following products: