Omega OS35 User Manual

Page 3

Advertising
background image

POWERED SMART OS35 SERIES DATASHEET

OS35 HIGHLIGHTS

•

Smart air purge assures maintenance free long term

accuracy

•

Smart continuous auto calibration

•

All digital system

•

Smart housing resists mechanical and thermal shocks

•

Smart emissivity shift and ambient radiation

correction

•

Easy plug and play installation

•

Lowest cost air purged, linearized sensor on the market

•

Optics of 3:1 & 20:1 available

•

Outputs of 0-5V, 0-10V, 4-20mA, & RS232

•

Temperature ranges from –22 - 1832 °F (-30 - 1000 °C)

•

LOW impedance, results in no offset errors due to

leakage current in your input device

•

Custom scaling and programming for

low emissivity materials and low temperatures available

OS35-3 (3:1 FOV)

3.71” x 1.37” x 0.76” (94.3 x 34.9 x 19.4 mm)

OS35-20 (20:1 FOV)

3.71” x 1.37” x 0.76”

(94.3 x 34.9 x 19.4 mm)

& 1.63” (41.3 mm) x 0.75” diameter snout

Temperature Range

Accuracy

Repeatability

OS35-3

-30-70 °C, 0-100 °C & 0-250 °C

±1 °C or 1%

± 1.5 °C or ± 1.5%

OS35-20

0-100 °C, 0-250 °C, & 0-500 °C

± 1.5 °C or ± 1.5%

0-1000 °C

± 1.5 °C or ± 2.0%

± 1 BIT

-30-70 °C = ± 0.1 °C
0-100 °C = ± 0.1 °C

0-250 °C = ± 0.25 °C

0-500 °C = ± 0.5 °C
0-1000 °C = ± 1 °C

Interchangeability

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

±1 °C (1.8 °F) or 0.5%

± 1.5 °C or ± 1.5%

MEASUREMENT SPECIFICATIONS

OUTLINE DRAWING

Advertising