Omnitron Systems Technology Fiber-to-Fiber Converter 100FF User Manual

Overview, Link modes, Front panel dip-switch settings

Advertising
background image

Page 7

Page 8

Page 9

Page 10

Page 11

Page 12

Page 1

Page 2

Page 3

Page 4

Page 5

Page 6

OVERVIEW:

The

iConverter

FF modules are fiber-to-fiber media

converters providing single-mode (SM) to multimode (MM),
dual fiber to single-fiber, wavelength conversion and
fiber extension. Fixed-fiber models are available for
Ethernet, Fast Ethernet, Gigabit Ethernet and
SONET/SDH applications. Small Form Pluggable (SFP)
model is protocol transparent and also supports Fibre
Channel.
The

iConverter

FF media converters can be used in an

unmanaged or managed fashion. When unmanaged, they
can be installed in a chassis without a Network
Management Module (NMM). To be managed, an NMM or
a media converter with built-in management must be
installed in the same chassis.

iConverter

®

100FF, OC3FF, OC12FF, 1000FF and xFF

Fiber-to-Fiber Converter User Manual

Port 1 (P1)

Port 2 (P2)

iConverter 1000FF Dual Fiber Modules

Connector

SC/SC

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx Wavelength

(nm)

8642-0

MM

220/550m

1

850

850

MM

220/550m

1

850

850

8642-1

MM

220/550m

1

850

850

SM

12km

1310

1310

8642-2

MM

220/550m

1

850

850

SM

34km

1310

1310

8642-3

MM

220/550m

1

850

850

SM

80km

1550

1550

8643-2

SM

12km

1310

1310

SM

34km

1310

1310

8643-3

SM

12km

1310

1310

SM

80km

1550

1550

ST/SC

iConverter 1000FF Single-Fiber Modules

8650-1

MM

220/550m

1

850

850

SM SF

20 km

1310

1550

8651-1

MM

220/550m

1

850

850

SM SF

20 km

1550

1310

8652-1

SM

12 km

1310

1310

SM SF

20 km

1310

1550

8653-1

SM

12 km

1310

1310

SM SF

20 km

1550

1310

8650-2

MM

220/550m

1

850

850

SM SF

40 km

1310

1550

8651-2

MM

220/550m

1

850

850

SM SF

40 km

1550

1310

8652-2

SM

12 km

1310

1310

SM SF

40 km

1310

1550

8653-2

SM

12 km

1310

1310

SM SF

40 km

1550

1310

1

62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm

multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.

iConverter 100FF Dual Fiber Modules

Connector

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx

Wavelength

(nm)

ST/ST

SC/SC

8620-1

8622-1

MM

5km

1310

1310

SM

30km

1310

1310

8620-2

8622-2

MM

5km

1310

1310

SM

60km

1310

1310

-

8622-3

MM

5km

1310

1310

SM

120km

1550

1550

ST/SC

SC/SC

iConverter 100FF Single-Fiber Modules

8630-1

8634-1

MM

5 km

1310

1310

SM SF

20 km

1310

1550

8631-1

8635-1

MM

5 km

1310

1310

SM SF

20 km

1550

1310

8630-2

8634-2

MM

5 km

1310

1310

SM SF

40 km

1310

1550

8631-2

8635-2

MM

5 km

1310

1310

SM SF

40 km

1550

1310

8632-1

8636-1

SM

30 km

1310

1310

SM SF

20 km

1310

1550

8633-1

8637-1

SM

30 km

1310

1310

SM

20 km

1550

1310

8632-2

8636-2

SM SF

30 km

1310

1310

SM

40 km

1310

1550

8633-2

8637-2

SM

30 km

1310

1310

SM SF

40 km

1550

1310

iConverter

OC3FF Dual Fiber Modules

Connector

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx

Wavelength

(nm)

ST/ST

SC/SC

8660-1

8661-1

MM

5km

1310

1310

SM

30km

1310

1310

8660-2

8661-2

MM

5km

1310

1310

SM

60km

1310

1310

8661-3

MM

5km

1310

1310

SM

120km

1550

1550

ST/SC

SC/SC

iConverter

OC3FF Single-Fiber Modules

8670-1

8674-1

MM

5 km

1310

1310

SM SF

20 km

1310

1550

8671-1

8675-1

MM

5 km

1310

1310

SM SF

20 km

1550

1310

8670-2

8674-2

MM

5 km

1310

1310

SM SF

40 km

1310

1550

8671-2

8675-2

MM

5 km

1310

1310

SM SF

40 km

1550

1310

8672-1

8676-1

SM

30 km

1310

1310

SM SF

20 km

1310

1550

8673-1

8677-1

SM

30 km

1310

1310

SM SF

20 km

1550

1310

8672-2

8676-2

SM

30 km

1310

1310

SM SF

40 km

1310

1550

8673-2

8677-2

SM

30 km

1310

1310

SM SF

40 km

1550

1310

iConverter OC12FF Dual Fiber Modules

Connector

SC/SC

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx

Wavelength

(nm)

8681-1

MM

220/550m

1

1310

1310

SM

12km

1310

1310

8681-2

MM

220/550m1

1310

1310

SM

34km

1310

1310

8681-3

MM

220/550m

1

1310

1310

SM

80km

1550

1550

SC/SC

iConverter OC12FF Single-Fiber Modules

8690-1

MM

220/550m

1

1310

1310

SM SF

20 km

1310

1550

8691-1

MM

220/550m

1

1310

1310

SM SF

20 km

1550

1310

8692-1

SM

12 km

1310

1310

SM SF

20 km

1310

1550

8693-1

SM

12 km

1310

1310

SM SF

20 km

1550

1310

1

62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm

multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.

iConverter xFF Dual Fiber Modules

Connector

SFP

Fiber Type

(Port 1

Port 2)

Distances

(Port 1

Port 2)

Tx

Wavelength

(nm)

Rx Wavelength

(nm)

8699-0

-

-

-

-

-

-

-

-

Refer to the SFP data sheet for supported transceivers.

LINK MODES:

In order to accommodate different user needs, the

iConverter

FF media converters support two different

linking modes.

Fig. 1 Link Modes

In Link Propagate (LP) mode (sometimes referred to as
Link Loss Carry Forward), a port transmits a Link signal
only when receiving a Link on the other front-plane port,
and a loss of a received Link at one port causes the
other front-plane port to stop transmitting its link signal.
For example, P1 transmits a Link only when receiving a
Link at P2 [Fig 1(a)].

In Remote Fault Detection (RFD) mode, a port transmits
a Link signal only when both itself and the other port are
receiving Link signals. A loss of a received Link signal
at a port is Looped-back and the port stops transmitting
a Link signal. The same loss of Link is propagated to
the other port which also stops transmitting the Link
signal. For example, the loss of Link into P2 causes
both P1 and P2 ports to stop transmission of the Link
signal [Fig 1(b)].

Note: Connecting two adjacent converters which
are both set to RFD is not permitted and will cause
a “deadly embrace” lockup.

Form: 040-08600-001L 3/08

FRONT PANEL DIP-SWITCH SETTINGS:

Fig. 2 Front Panel Dip-Switches

Link Segment/Link Propagation “LS/LP” Dip-Switch:
This DIP-Switch has no affect. The LS function of this
DIP-Switch has been disabled to enhance compatibility
with third-party fiber optic devices.

iConverter

Fiber-to-Fiber media converters normally operate in LP
mode.

Remote Fault Detection Switch “RFD” Dip-Switch:
When in the Remote Fault Detection “RFD” position,
the Remote Fault Detection mode is enabled and LP
mode is disabled. When in the Normal “Norm” position
(factory setting), Remote Fault Detection is disabled
and LP mode is enabled.

LED INDICATORS:

LED

Color

Description

Pwr:

Yellow

On--Power on

Lk/Rx (P1):

Green

On--Link

Lk/Rx (P2):

Green

On--Link

Warning

The operating description in this Instruction Manual is for
use by qualified personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.

Warranty

This product is warranted to the original purchaser against
defects in material and workmanship for a period of 2
YEARS from the date of shipment. A LIFETIME limited
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90 days
from the date of shipment. To register, complete and mail
or fax the enclosed Registration Card to the indicated
address. You may also register your product on the internet
at www.omnitron-systems.com/Register. During the
warranty period, Omnitron will, at its option, repair or replace
a product which is proven to be defective.

For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense. Omnitron
will pay the shipping charge to return the product to Buyer’s
designated US address (within the 48 contiguous states
and the District of Columbia) using Omnitron’s standard
shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment, Buyer-
supplied interfacing, unauthorized modifications or
tampering with equipment (including repairs of equipment
by personnel not specifically authorized and certified by
Omnitron, or misuse, or operating outside the environmental
specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or
improper site preparation or maintenance.

No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.

Technical Support:

For help with this product, contact our Technical Support:
Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address:

Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA

E-mail:

[email protected]

URL:

www.omnitron-systems.com

MOUNTING AND CABLE ATTACHMENT:

iConverter

modules are hot-swappable and can be installed

into any chassis in the

iConverter

family.

1. Carefully slide the

iConverter

module into installation slot,

aligning the module with the installation guides. NOTE:
Ensure that the module is firmly seated against backplane.

2. Secure the module by securing panel fastener screw

(attached to module) to chassis front.

3. When using an SFP model (8699-0), insert the SFP

Fiber transceiver into the SFP receptacle on the module.
Note: The release latch of the SFP Fiber transceiver
must be in the closed position before insertion.

4. Attach an appropriate multimode or single-mode fiber

cable to each fiber connector. The transmit cable (Tx)
must attach to the receive side on the other device; the
receive cable (Rx) must attach to the transmit.

5. When using single-fiber (SF) models, the Tx

wavelength on one end must match the Rx wavelength
on the other and the converters must be used in
matched pairs (example: model 8670-1 must be
matched with model 8671-1).

FIBER-TO-FIBER SPECIFICATIONS:

Model Type

100FF

1000FF

OC3FF

OC12FF

xFF

Protocols

100BASE-FX,
100BASE-BX,

100BASE-LX

1000BASE-SX,

1000BASE-LX,
1000BASE-ZX,
1000BASE-BX

OC-3

OC-12

100BASE-FX,
1000BASE-X,

OC-3, OC-12

Fibre Channel

Maximum
Data Rate

155Mbps

1.25Gbps

155Mbps

1.25Gbps

1.25Gbps

Fiber
Connectors

SC, ST,

Single-Fiber

SC

SC,

Single-Fiber

SC

SC, ST,

Single-Fiber

SC

SC,

Single-Fiber

SC

SFP

Controls

Link Propagate, Remote Fault Detection

LED
Displays

Power,

Fiber Optic Link (2)

Dimensions

W:0.85" x D:4.5" x H:2.8"

Weight

8 oz.

Compliance

UL, CE, FCC Class A,

NEBS Level 3

Power
Requirement
(typical)

0.5A @

3.3VDC

0.5A @

3.3VDC

0.5A @

3.3VDC

0.5A @

3.3VDC

0.5A @

3.3VDC

Temperature

Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C

Humidity

5 to 95%

(non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

1,300,000

Advertising