INSTALLATION OF PSW-141 PRESSURE

SWITCH

Each switch is calibrated in the vertical

position. It is recommended the switch be

mounted in the vertical position, as viewed

in Figure 1. Any adjustments to the

setpoint or deadband should be performed

with the instrument in the mounted position.

The PSW-141 differential pressure switch is suitable for clean air

or inert gas applications. If dust is present, a small in-line filter is

recommended to insure long, trouble-free operation. The normal

operating temperature range is from 0°C to 45°C (32°F to 115°F),

and the normal humidity range from 10% to 90% R.H.
Air connections are by means of 3/16” (4.75mm) barbed fittings

suitable for 1/4” O.D. polyethylene tubing (6mm), 1/8” I.D. Tygon or

polyurethane tubing (3 - 4mm).

The two mounting holes are 0.19” (4.8mm) in diameter and are

suitable for #8 or #10 mounting screws.

Electrical connections are by means of 3/8” terminal strips with #6

screws.

Spacing between mounting holes: 4.75 inches (121 mm).

Care should be taken not to exceed the maximum overpressure.

NOTE:

Figure 1

Power consumption is .35 W for the DC powered units,

1.70 W for the 24 Vac and 1.90 W for the 120 Vac.
The power supply leads are connected to the two leftmost termi-

nals (terminals 1 and 2) on the terminal strip. The relay terminals

are accessed across terminals 3, 4, and 5, refer to Figure 1.
The pressure switch comes with Setpoint and Deadband Adjust-

ments. These are adjusted at the factory to activate on either fall-

ing or rising pressure. The setpoint is factory set to activate at the

maximum pressure. The deadband is set to 5% of the maximum

pressure.

SETPOINT/DEADBAND ADJUSTMENT PROCEDURE
The set point and deadband are field adjustable so long as an

accurate pressure source is available and a qualified technician

performs the adjustments. The low pressure switches are extremely

sensitive to sudden pressure changes.
To gain access to the Setpoint or Deadband potentiometers re-

move the black hole plugs above the Setpoint and Deadband la-

bels, located on the top left of the instrument. To access either

potentiometer use a slotted 3/32” screw driver.
Connect the switch to its appropriate power supply.
Connect an ohmmeter to the relay contacts “common” and “nor-

mally closed” or “normally open”. If a switch was ordered with a

relay activated on “Rising Pressure” and the ohmmeter terminals

are connected to the “normally closed” and “common” of the relay,

with no pressure applied, the ohmmeter should read 0 or closed,

refer to Table 2.
Deadband Adjustment

To set the deadband to zero, turn the Deadband potentiometer

fully counter-clockwise . Zero deadband will cause the relay to

chatter. It is recommended that some amount of deadband be

used. Turning the deadband potentiometer clockwise increases

the deadband.

Setpoint Adjustment

Apply full pressure, (or the pressure at which the setpoint is to

activate). Rotate the 20 turn Setpoint potentiometer, until the ohm-

meter changes state. Turn clockwise to increase the set point and

counter-clockwise to decrease the set point
Slowly decrease the pressure until the relay deactivates. The dif-

ference between the pressure at which the relay deactivates and

the pressure at which the relay activates is the deadband. If more

deadband is required, turn the deadband potentiometer and re-

peat the previous steps. Adjustment of the deadband will have a

slight effect on the set point, therefore it will be necessary to re-

peat these steps several times.
RELAY SPECIFICATIONS

The output of the SPDT (1 Form C) relay contact is rated at:

5A @ 30 VDC/120 VAC Resisitive

4A @ 240 VAC Resistive

Gold-plated relay contacts.

Electrical life expectancy: 100 x 10

3

ops. minimum @ 5A

Isolation between coil and contacts: 2000 VAC 1 minute

Maximum switched power: 600 VA (AC) or 120 W (DC)

Operate Time: 8 ms, max (Excluding Bounce)

Release Time: 4 ms, max (Excluding Bounce)

Table 2

y

a

l

e

R

:

t

u

p

t

u

O

r

e

t

e

m

m

h

O

y

l

l

a

m

r

o

N

d

n

a

n

o

m

m

o

C

d

e

s

o

l

C

e

r

u

s

s

e

r

P

g

n

i

s

i

R

e

r

u

s

s

e

r

P

g

n

il

l

a

F

e

r

u

s

s

e

r

P

d

e

il

p

p

A

o

N

e

r

u

s

s

e

r

P

)

0

(

d

e

s

o

l

C

)

L

O

(

n

e

p

O

e

r

u

s

s

e

r

P

ll

u

F

)

L

O

(

n

e

p

O

)

0

(

d

e

s

o

l

C

e

l

b

a

T

e

r

u

s

s

e

r

p

r

e

v

O

y

r

a

t

n

e

m

o

M

e

f

a

S

m

u

m

i

x

a

M

e

g

n

a

R

e

r

u

s

s

e

r

p

r

e

v

O

h

s

il

g

n

E

c

i

r

t

e

M

h

s

il

g

n

E

c

i

r

t

e

M

H

"

0

.

1

o

t

"

1

.

0

2

O

H

"

0

.

0

1

o

t

"

0

.

2

2

O

H

"

1

1

2

D

I

S

P

5

o

t

O

D

I

S

P

5

1

o

t

D

I

S

P

6

D

I

S

P

0

3

o

t

D

I

S

P

6

1

a

P

0

5

2

o

t

5

2

a

P

k

5

.

2

o

t

5

.

0

a

P

k

5

3

o

t

7

.

2

a

P

k

0

0

1

o

t

0

4

a

P

k

0

0

2

o

t

0

1

1

H

"

8

2

O

D

I

S

P

5

D

I

S

P

0

2

D

I

S

P

0

3

D

I

S

P

0

6

a

P

k

2

a

P

k

5

3

a

P

k

0

4

1

a

P

k

0

0

2

a

P

k

0

2

4

PSW-141 Series M-3488 / 0011

Advertising