Omega Speaker Systems Dual Thermocouple Over the Internet iSE-TC User Manual

Page 40

Advertising
background image

36

4.5.1 HTTPget using Port 1000 (continued)

httpget -r -S “*SRTC\r” 192.168.1.200:2000

where:

-r –S are parameters needed for the command string

*SRTC is the command as the following:

*SRTC

Read the temperature in C (Channel 1)

*SRTF

Read the temperature in F (Channel 1)

*SRHC

Read temperature in C (Channel 2)

*SRHF

Read temperature in F (Channel 2)

*SRDC

Read the differential in C

*SRDF

Read the differential in F

*SRA1

Read temperature setpoints (Channel 1)

*SRA2

Read temperature setpoints (Channel 2)

*SRB

Read the temperature in C, (both Channel 1 and Channel 2)

*SRYS

Indicate AC or DC power and battery status

*SRYRST

Reset Power on iSE

*SR_XD1

Exclude alarm 1 (disable alarm 1 function)

*SR_XD2

Exclude alarm 2 (disable alarm 2 function)

*SR_XC1

Reset relay 1 latch condition

*SR_XC2

Reset relay 2 latch condition

*SR_XE1

Include alarm 1 (enable alarm 1 function)

*SR_XE2

Include alarm 2 (enable alarm 2 function)

*SR_XP1

Close relay 1 for < 200 mSec

*SR_XP2

Close relay 2 for < 200 mSec

*SR_XH1

Close relay 1

*SR_XH2

Close relay 2

*SR_XL1

Open relay 1

*SR_XL2

Open relay 2

*SRT2

Status of Contact 1 (Disable, Normal, Active)

*SRH2

Status of Contact 2 (Disable, Normal, Active)

*SRD2

Status of the Output associated with the Contacts (Active High,

Active Low)

\r is the carriage return termination character

192.168.1.200 is an IP address

2000 is a socket port number

Response:

076.6 (in Deg.F 35)