Select unit.

Press and hold

✱ and use the ▲ or ▼ buttons to scroll

through the unit selection list until the

correct unit is displayed. Release the

buttons.

The display will read selected unit e.g.

Press ▲ once

The display will now read

3

Select SP1

(Main setpoint output device)

Note:

Dual Relay and Dual SSd Output Options

Models CN9411 and CN9422 have their outputs

pre-configured. (see page 22)

Press and hold ✱ and use the ▲ or ▼ buttons to select

SSd

or

rLY

as required.

The controller will now read selected output device e.g.

Quick Start

QUICK START

1b

4

To enter initial configuration into
controller memory

Press and hold

both ▲ and ▼ buttons for 3 seconds.

The upper display will now alternate

ParK

and measured variable (temperature)

(eg.

23

)

ParK

is displayed because

a setpoint has not yet been entered as

shown by the lower display

To display setpoint

Press and hold ✱ The displays will now read

unit

(eg.

°C

) and

0

To enter setpoint

Press and hold ✱ and use ▲ button to increase or ▼

button to decrease the reading and

scroll to required setpoint value. (The

digit roll-over rate increases with time).

THE CONTROLLER IS NOW OPERATIONAL

WITH FACTORY SETTINGS

Note:

For precise control of an application the controller

may need to be TUNED. Please study section

headed FUNCTIONS and OPTIONS before moving

to the section on AUTOTUNE.

UNIT

*C

SPI.D

NONE

SPI.D

SSD

PARK

0

*C

0