Omnitron Systems Technology miConverter GX/T User Manual

Page 2

Advertising
background image

Warning

The operating description in this Instruction Manual is for use by
qualified personnel only. To avoid electrical shock, do not perform any
servicing of this unit other than that contained in the operating
instructions, unless you are qualified and certified to do so by
Omnitron Systems Technology, Inc.

Warranty

This product is warranted to the original purchaser against defects
in material and workmanship for a period of TWO YEARS from the
date of shipment. A LIFETIME warranty may be obtained by the
original purchaser by REGISTERING this product with Omnitron
within 90 days from the date of shipment. TO REGISTER,
C O M P L E T E A N D M A I L O R F A X T H E E N C L O S E D
REGISTRATION FORM. Or you may register your product on the
Internet at www.omnitron-systems.com. During the warranty period,
Omnitron will, at its option, repair or replace a product which is
proven to be defective.

For warranty service, the product must be sent to an Omnitron designated
facility, at Buyer’s expense. Omnitron will pay the shipping charge to
return the product to Buyer’s designated US address using Omnitron’s
standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper
or inadequate use and/or maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including removal of
equipment cover by personnel not specifically authorized and certified
by Omnitron), or misuse, or operating outside the environmental
specification of the product (including but not limited to voltage, ambient
temperature, radiation, unusual dust, etc.), or improper site preparation
or maintenance.

No other warranty is expressed or implied. Omnitron specifically
disclaims the implied warranties of merchantability and fitness for any
particular purpose.

LED INDICATORS

LED

Color

Description

Pwr:

Yellow

On--Power / Blink--test

Fiber FDX:

Green

On--Full-Duplex detected

Lk/Act

Green

On--Link / Blink--activity

AN:

Green

On--UTP Auto-Neg. enabled

10:

Green

On--10 Mbps link / Blink-activity

100:

Green

On--100 Mbps link / Blink-activity

1000:

Green

On--1000 Mbps link / Blink-activity

UTP FDX:

Green

On--Full-Duplex detected

Mounting and Cable Attachment

iConverter

modules are hot-swappable and can be

installed into any chassis in the

iConverter

family.

1. Carefully slide the iConverter module into the

installation slot, aligning the module with the
installation guides. NOTE: Ensure that the module is
firmly seated against the backplane.

2. Secure the module by securing the panel fastener

screw (attached to module) to the chassis front.

3. Attach the UTP port via a category 5 cable to a

1000BASE-T, 100BASE-TX or 10BASE-T Ethernet
device.

4. Attach the fiber port via an appropriate multimode

or single-mode fiber cable to a 1000BASE-X Ethernet
device. The

iConverter

transmit (Tx) must attach to

the receive side on other device; the receive (Rx)
must attach to the transmit.

5. When using single-fiber (SF) media converter models,

the Tx wavelength on one end has to match the Rx
wavelength on the other. Note that based on this
guideline, the SF media converter models must be used
in pairs, such as the 8530-1 matched with the 8531-1.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and exclusive
remedies. Omnitron shall not be liable for any direct, indirect, special,
incidental, or consequential damages, whether based on contract, tort,
or any legal theory.

Form: 040-08520-001E 9 /07

BOARD MOUNTED DIP-SWITCHES

10
10-100
MANX

=
=
=

UTP 10Mbps
UTP 10/100Mbps
Manual Crossover

BPAEN
BPBEN
MAN

=
=
=

Backplane “A” Enabled
Backplane “B” Enabled
P1 Manual FO

100

1000

AX

=
=
=

MAN

= P2 Manual UTP

P2 Auto Negotiate

UTP 100Mbps

UTP 1000Mbps
Auto Crossover

AN

=

Off
Off

P1 Auto Negotiate

ON

HD

= P2 Half Duplex

FD

=

P2 Full Duplex

AN

=

Fig. 4 Board Mounted DIP-Switches

Backplane A Enable DIP-Switch (BPAEN)

When the “BPAEN” DIP-Switch is in the “ON” position (right),
the iConverter GX/T module A backplane Ethernet port is
enabled. This port allows connectivity to an adjacent module.
When the “BPAEN” DIP-Switch is in the “Off” position (left,
factory setting), the A port is isolated from the backplane.

Backplane B Enable “BPBEN” DIP-Switch

When the Backplane B Enable “BPBEN” DIP-Switch is
in the “ON” position (right), the iConverter GX/T module
B backplane Ethernet port is enabled. This port allows
connectivity to an adjacent module. When the “BPBEN”
DIP-Switch is in the “Off” position (left, factory setting),
the B port is isolated from the backplane.

Fiber Auto/Manual P1 “AN/MAN” DIP-Switch

Setting this DIP-Switch to P1 Auto-Negotiate “AN”
(factory setting) enables the Fiber Port to determine
duplex mode automatically. If the connected device
cannot provide the proper signal to indicate its own
mode of operation, this DIP-Switch should be set to P1
Manual “MAN.” This feature allows connections with
devices that do not auto-negotiate properly.

NOTE: When the fiber port is in Manual Mode,
sometimes a link-up will not occur with other devices.
Both devices must be set to the same mode (either
Manual or Auto-Negotiate) for the link-up to occur.

UTP Auto/Manual P2 “AN/MAN” DIP-Switch

Setting the P2 Auto/Manual Negotiate DIP-Switch to
Auto-Negotiate “AN” (factory setting) enables the
UTP port to determine the speed and duplex mode
automatically. If the connected device cannot provide
the proper signal to indicate its own mode of operation,
this DIP-Switch should be set to P2 Manual “MAN.”
This feature allows connections with devices that do
not auto-negotiate properly.

NOTE: Attaching an auto-negotiating UTP port to a non
auto-negotiating (manual/forced/hard-coded) UTP port
may result in an unpredictable port setting with excessive
collisions and poor link performance. When operating in
manual mode, both mating ports MUST be set manually to
the same speed and duplex mode.

Gigabit devices typically function only in Auto-Negotiate
Mode. 1000 Manual Mode is not a valid mode and will
result in an undefined response. Use Manual mode only
when selecting the 10 or 100 mode.

UTP Full/Half-Duplex P2 “FD/HD” DIP-Switch

When the UTP P2 Auto/Manual DIP-Switch (described
above) is in the P2 Manual “MAN” position, the UTP P2
Full/Half Duplex “FD/HD” DIP-Switch selects the duplex
mode for the UTP port. When set to Full-Duplex “FD”
(factory setting), the UTP port operates in Full-Duplex
mode. When P2 is set to Half-Duplex “HD,” the UTP
port operates in Half-Duplex mode.

UTP 10/100 P2 “10/100” DIP-Switch

When the UTP P2 Auto/Manual DIP-Switch is in the
Auto-Negotiate “AN” position and the “10-100/1000”
DIP-Switch (described below) is set to “10-100,” the
“10/100” DIP-Switch determines the highest speed of
the UTP P2 port in the following manner:

When the “10/100” DIP-Switch is set to the “100” position,
P2 operates at 100Mbps or less, depending on the speed
of the connected device.

When the “10/100” DIP-Switch is set to the “10” position,
P2 operates only at 10Mbps.

When the UTP P2 Auto/Manual DIP-Switch is in the Manual
“MAN” position and the UTP “10-100/1000”
DIP-Switch (described below) is set to “10-100,” the
“10/100” DIP-Switch determines the speed of the UTP P2
port. When set to “100” (factory setting), the UTP port will
operate at 100Mbps. When set to “10,” the UTP port will
operate at 10Mbps.

UTP 10-100/1000 P2 “10-100/1000” DIP-Switch

When the P2 “AN/MAN” DIP-Switch is set to the
Auto-Negotiate “AN” position, the “10-100/1000”
DIP-Switch operates in the following manner:

When set to “1000,” P2 operates at 1000Mbps or less,
depending on the speed of the connected device.
When set to the “10-100” position, the speed is selected
by the UTP “10/100” DIP-Switch.

When the P2 “AN/MAN” DIP-Switch is set to Manual
“MAN” mode, the “10-100/1000” DIP-Switch must be
set to the “10-100” position and the speed is selected
by the “10/100” DIP-Switch.

NOTE: Setting the “10-100/1000” DIP-Switch to the
“1000” position when in Manual mode is not permitted
(per the IEEE 802.3 standard) and will result in
unpredictable port behavior.

Auto/Manual Crossover Enable P2 “AX/MANX”
DIP-Switch

When the Manual/Auto Crossover Enable DIP-Switch
is set to Auto Crossover “AX” (factory default), the
front panel crossover switch is disabled and the RJ-45
crossover is selected automatically. When it is set to
Manual Crossover “MANX,” the front panel RJ-45
Manual Crossover DIP-Switch is enabled to allow a
manual setting in either Crossover or Straight-Through
connection.

Page 9

Page 10

Page 11

Page 12

Page 15

Page 16

TECHNICAL SUPPORT:

For help with this product, contact our Technical Support:

Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address:

Omnitron Systems Technology, Inc.

140 Technology Dr., #500

Irvine, CA 92618 USA

E-mail:

[email protected]

URL:

www.omnitron-systems.com

Model Type

GX/T

Protocols

10BASE-T, 100BASE-TX,

1000BASE-T,

1000BASE-SX/LX

UTP
Connectors

RJ-45

Fiber
Connectors

SC, MT-RJ, LC, Single-Fiber

SC

Controls

BP Enable, X-Over, LS/LP,

RFD, SFD, UTP Auto/Man,

10/100/1000, UTP FDX/HDX,

F/O Auto/Man

LED Displays

Power, FO link, UTP link, Auto,

FDX/HDX, 10/100/1000

Dimensions

W:0.85" x D:4.5" x H:2.8"

Weight

8 oz.

Compliance

UL, CE, FCC Class A

Power
Requirement

1.4A @ 3.3VDC (typical)

Temperature

Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

830,000

Advertising