Operation, Sample applications, Specifications ordering information – Omnitron Systems Technology OmniRepeater 400 AS400/3X 5250 User Manual

Page 2: Omnitron systems technology, inc

Advertising
background image

n

Protocol:

IBM 5250 and 5250 Express for Systems
AS/400, 3X

n

Interface:

Link:

One (1) Twinax, One (1) Fiber or
One (1) RJ11/45, One (1) Fiber

Port:

One (1) Twinax or
One (1) RJ11/45
(RJ11 pins 3-4, RJ45 pins 4-5 are standard)

n

Cable Types:

Twinax:

IBM 7362229 or equivalent

UTP:

Category 3 (EIA/TIA 568) or higher,
(shorter distance @ lower grade)

n

Data Rate:

Standard 5250:

1 Mbps -2%, +4%

5250 Express:

1 or 2 Mbps -2%, +4%

n

Supported Distances:

Twinax:

5,000 ft.

UTP:

3,000 ft.

Multimode Fiber:

15,000 ft.

Singlemode Fiber:

30,000 ft.

n

Physical features:

Rackmounted:

W:19.0"xD:6.0"xH:1.75"

Tabletop:

W:17.5"xD:6.0"xH:1.75"

Weight:

7 lbs.

n

Power:

115 or 230 VAC, 150 mA

n

Temperature:

Operating:

0 to 40 degrees C

Storage:

-40 to 75 degrees C

n

Humidity:

Up to 90% (non condensing)

Trademarks are owned by their respective companies
OmniMux, OmniStar, OmniRepeater are trademarks of
Omnitron Systems Technology, Inc.
Specifications subject to change without notice.
©1993-2001Omnitron Systems Technology, Inc.

091-02651-002 11/01

Omnitron Systems

Technology, Inc.

27 Mauchly #201, Irvine, CA 92618

Tel: (949) 250-6510 Fax: (949) 250-6514

E-mail: [email protected]

http://www.omnitron-systems.com

OPERATION

Inputs: The OmniRepeater

400 is built around a Digital Phased

Locked Architecture (PLA). This technology allows effective
discrimination between true data and noise. The incoming
Manchester encoded data is sampled at 16 samples per bit, which
facilitates digital filtering of noise and crosstalk. A unique clock
recovery facilitates the capture of data with rate variations of -2%
to +4%.

Processing: Once the data is recovered and synchronized, it is
processed. The processor analyzes the frame header. If a legal
header is detected, the port is “marked” active and the data is
allowed to flow through the repeater.

Outputs: The retransmitted data is regenerated, reclocked and
lost sync bits are recovered. The data is reclocked at 50% duty
cycle to eliminate clock jitter. The signal is restored to nominal
amplitude and the pre-distortion logic compensates for
anticipated phase shift and attenuation.

Displays: True data activity and parity errors are displayed by
green and red LEDs. The green activity LEDs assist in monitoring
signal strength while the red Parity Error LEDs assist in
monitoring connectivity quality, signal strength, impedance
mismatches and reflections.

SAMPLE APPLICATIONS

The following picture depicts three typical applications of the
OmniRepeater

400:

In the first case, the host (a) twinax signal is repeated and reclocked
by the OmniRepeater (b) and workstation distance from the host
is extended to 10,000 feet (c).

In the second case, the OmniRepeater (d) converts the twinax data
to fiber and then back to twinax via a second OmniRepeater (e).

In the third case, twinax is converted to fiber (g) via the
OmniRepeater

and then to twisted pair via an OmniMux

(h)

which delivers it to the workstations (k).

SPECIFICATIONS

ORDERING INFORMATION

Standard

5250

5250

Express

Description

2651

2661

Twinax to Twinax and Fiber

2653

2663

Twinax to Twinax Only

while providing superior noise and crosstalk immunity.

The Express models operate with both the 5250 and 5250 Express
protocols. Each port provides data rates of 1 Mbps for standard
5250 and 2 Mbps for 5250 Express protocol.

The OmniRepeater

400 is completely software-transparent and

no setup or any changes are required.

Advertising
This manual is related to the following products: